Figures |
FIGURE 1-1 Netra 240 Server
FIGURE 2-1 Finger Holds on Bezel
FIGURE 2-2 Installing the Air Filter in the Front Bezel
FIGURE 3-1 Contents of the Hardmount 19-Inch 4-Post Kit
FIGURE 3-2 Securing the Hardmount Brackets to the Server
FIGURE 3-3 Attaching the Rear Mount Support Brackets
FIGURE 3-4 Securing the Front of the Server to the Rack
FIGURE 3-5 Securing the Rear of the Server to the Rack
FIGURE 3-6 Contents of the Sliding Rail 19-Inch 4-Post Kit
FIGURE 3-7 Securing the Hardmount Bracket to the Server
FIGURE 3-8 Dismantling the Slide
FIGURE 3-9 Fixing the Glides to the System Chassis
FIGURE 3-10 Securing the Brackets to the Rack
FIGURE 3-11 Securing the Slide to the Brackets
FIGURE 3-12 Sliding the System Into the Rack
FIGURE 3-13 Securing the Front of the System to the Rack
FIGURE 3-14 Contents of the Hardmount 600 mm 4-Post Kit
FIGURE 3-15 Loosening the Adjustable Rail Screws
FIGURE 3-16 Securing the Front of the Adjustable Rails to the Rack
FIGURE 3-17 Securing the Rear of the Adjustable Rails to the Rack
FIGURE 3-18 Installing the Rear Flange Onto the Adjustable Rail
FIGURE 3-19 Securing the Side Rails to the Server
FIGURE 3-20 Sliding the Server Onto the Adjustable Rails
FIGURE 3-21 Securing the Rear of the Server to the Rear Flanges
FIGURE 3-22 Securing the Front of the Server to the Front of the Rack
FIGURE 3-23 Contents of the Hardmount 23-Inch 2-Post Kit
FIGURE 3-24 Securing the Side Brackets to the Side of the Server
FIGURE 3-25 Installing the Rail Guides in the Rack
FIGURE 3-26 Installing and Securing the Server in the 2-Post Rack
FIGURE 3-27 Installing a Screw on the Shallowest Rack Position on the Rear Plate
FIGURE 3-28 Installing the Rear Plate to the Side Bracket
FIGURE 3-29 Securing the Rear Plate to the Side Bracket
FIGURE 3-30 Contents of the Hardmount 19-Inch 2-Post Kit
FIGURE 3-31 Securing the Side Brackets to the Side of the Server
FIGURE 3-32 Installing and Securing the Server in the 2-Post Rack
FIGURE 3-33 Installing Screws on the Shallowest Rack Position on the Rear Plate
FIGURE 3-34 Installing the Rear Plate to the Side Bracket
FIGURE 3-35 Securing the Rear Plate to the Rack
FIGURE 4-1 Rear Cable Connectors (DC Server)
FIGURE 4-2 Rear Cable Connectors (AC Server)
FIGURE 4-3 Location of Chassis Grounding Studs
FIGURE 4-4 Gigabit Ethernet Port Pin Numbering
FIGURE 4-5 Network Management Port Pin Numbering
FIGURE 4-6 Serial Management Port Pin Numbering
FIGURE 4-7 Serial Port (10101) Pin Numbering
FIGURE 4-8 Alarm Port Pin Numbering
FIGURE 4-9 USB Ports Pin Numbering
FIGURE 4-10 SCSI Port Pin Numbering
FIGURE 5-1 DC Connection Parts
FIGURE 5-2 Stripping the Insulation From the Wire
FIGURE 5-3 Opening the DC Input Plug Cage Clamp Using the Cage Clamp Operating Lever
FIGURE 5-4 Opening the Cage Clamp Using a Screwdriver
FIGURE 5-5 Assembling the DC Input Power Cable
FIGURE 5-6 Inserting the Bottom Portion of the Strain Relief Housing
FIGURE 5-7 Routing the Wires out of the Bottom Portion of the Strain Relief Housing
FIGURE 5-8 Securing the Wires to the Strain Relief Housing
FIGURE 5-9 Assembling the Strain Relief Housing
FIGURE 5-10 DC Connector Locations
FIGURE 5-11 Connecting the DC Input Power Cable to the DC Connectors
FIGURE 5-12 Disconnecting the DC Input Power Cable From the DC Connector
FIGURE 5-13 Connecting the AC Power Cords to the AC Power Inlet Connectors
FIGURE 6-1 Patch Panel Connection Between a Terminal Server and a Netra 240 Server
FIGURE 7-1 Finger Holds on Bezel
FIGURE 7-2 Rotary Switch Set to Normal Position
FIGURE A-1 Location of the Front Indicators
FIGURE A-2 Hard Drive Indicators
FIGURE A-3 Rear Indicators on the Netra 240 Server
FIGURE A-4 Ethernet Network Indicators