A P P E N D I X  B

System Specifications

This appendix provides the following specifications for the Sun Fire V490 server:


Physical Specifications

The dimensions and weight of the system are as follows.

Measurement

U.S

Metric

Height

8.75 in

222 mm

Width

17.5 in

446 mm

Depth

24 in

610 mm

Weight

Minimum

Maximum

 

79 lbs

97 lbs

 

35.83 kg

44 kg

Power Cord

8.2 ft

2.5 m



Electrical Specifications

The following table provides the electrical specifications for the system.



Note - All electrical specifications apply to a fully configured system.



Parameter

Value

Input

 

Nominal Frequencies

50 or 60 Hz

Nominal Voltage Range

Auto Ranging 200-240 VAC

Maximum Current AC RMS

8A @ 200-240 VAC

Maximum AC Power Consumption

1600 W

Maximum Heat Dissipation

5459 BTU/hr



Environmental Specifications

The operating and non-operating environmental specifications for the system are as follows.

Parameter

Value

Operating

Temperature

5°∞ C to 35°C (41°F to 95°F)--IEC 60068-2-1&2

Humidity

20% to 80% RH noncondensing; 27°C (81°F) wet bulb--
IEC 60068-2-3&56

Altitude

0 to 3000 meters (0 to 10,000 feet)--IEC 60068-2-13

Vibration

.0001 (z-axis only) G2/Hz, 5-150 Hz, -12db/octave slope, 150-500 Hz-- IEC 60068-2-13

Shock

3g peak, 11 milliseconds half-sine pulse--IEC 60068-2-27

Declared Acoustics

72 DbA

Non-Operating

 

Temperature

-20°C to 60°C (-4°F to 140°F)--IEC 60068-2-1&2

Humidity

95% RH noncondensing--IEC 60068-2-3&56

Altitude

0 to 12,000 meters (0 to 40,000 feet)--IEC 60068-2-13

Vibration

.001 (z-axis only) G2/Hz, 5-150 Hz, -12db/octave slope, 150-500 Hz-- IEC 60068-2-13

Shock

10g peak, 11 milliseconds half-sine pulse--IEC 60068-2-27

Handling Drops

25 mm (10 in)

Threshold Impact

1 meter/second



Agency Compliance Specifications

The system complies with the following specifications.

Category

Relevant Standards

Safety

UL 60950, CB Scheme IEC 60950, CSA C22.2 No. 60950-00 from UL,

TUV EN 60950

RFI/EMI

47 CFR 15B Class A

EN55022 Class A

VCCI Class A

ICES-003

AS/NZ 3548

CNS 13438

Immunity

EN55024

IEC 61000-4-2

IEC 61000-4-3

IEC 61000-4-4

IEC 61000-4-5

IEC 61000-4-6

IEC 61000-4-8

IEC 61000-4-11



Clearance and Service Access Specifications

Minimum clearances needed for servicing the system are as follows.

Blockage

Required Clearance

Front blockage only

36 in (92 cm)

Rear blockage only

36 in (92 cm)

Front and rear blockage

Front clearance

Rear clearance

36 in (92 cm)

36 in (92 cm)

36 in (92 cm)