A P P E N D I X  C

Event Messages

This appendix lists the following event messages:

There are three categories of events.

TABLE C-1 Categories of Event Messages

Category

Description

Alert

 

Errors that need to be attended to immediately; might require reconnecting cables, replacing a component, or rebuilding a drive.

Warning

 

 

Errors that might indicate a temporary condition, a possible component problem, or the need to adjust controller parameters. Press Esc to clear message.

Notification

 

Informational message sent from controller firmware; press Esc to clear message.



Controller Events

The controller records all array events during power on; it records up to one thousand events.



caution icon

Caution - Powering off or resetting the controller causes an automatic deletion of all recorded event logs.



Alerts

[0104] Controller ALERT: SDRAM ECC Single-bit Error Detected

[0105] Controller <primary/secondary> SDRAM ECC <multi-bits/single-bit> Error Detected

[0110] CHL:_ FATAL ERROR (_)

[0111] Controller ALERT: Redundant Controller Failure Detected

[0114] Controller ALERT: Power Supply Unstable or NVRAM Failed

Warnings

[0107] Memory Not Sufficient to Fully Support Current Config.

Notifications

[0111] Controller NOTICE: Redundant Controller Firmware Updated

[0181] Controller Initialization Completed

[0187] Memory is Now Sufficient to Fully Support Current Config.

[0189] NVRAM Factory Defaults Restored

[0189] NVRAM Restore from Disk is Completed

[0189] NVRAM Restore from File is Completed


SCSI Drive Events

SCSI drive event messages include:

Warnings

[1101] CHL:_ ID:_ SCSI Target ALERT: Unexpected Select Timeout

[1102] CHL:_ ID:_ SCSI Target ALERT: Gross Phase/Signal Error Detected

[1103] CHL:_ ID:_ SCSI Target ALERT: Unexpected Disconnect Encountered

[1104] CHL:_ ID:_ SCSI Drive ALERT: Negotiation Error Detected

[1105] CHL:_ ID:_ SCSI Target ALERT: Timeout Waiting for I/O to Complete

[1106] CHL:_ ID:_ SCSI Target ALERT: SCSI Parity/CRC Error Detected

[1107] CHL:_ ID:_ SCSI Drive ALERT: Data Overrun/Underrun Detected

[1108] CHL:_ ID:_ SCSI Target ALERT: Invalid Status/Sense Data Received (_)

[110f] CHL:_ LIP(_ _) Detected

[110f] CHL:_ SCSI Drive Channel Notification: SCSI Bus Reset Issued

[110f] CHL:_ SCSI Drive Channel ALERT: SCSI Bus Reset Issued

[1111] CHL:_ ID:_ SCSI Target ALERT: Unexpected Drive Not Ready

[1112] CHL:_ ID:_ SCSI Drive ALERT: Drive HW Error (_)]

[1113] CHL:_ ID:_ SCSI Drive ALERT: Bad Block Encountered - _ (_)

[1114] CHL:_ ID:_ SCSI Target ALERT: Unit Attention Received

[1115] CHL:_ ID:_ SCSI Drive ALERT: Unexpected Sense Received (_).



Note - The three-digit code in parentheses for warning 1115 provides additional information about the drive error. The first of these three digits represents the SCSI Sense Key. The remaining two digits represent the Additional Sense Code (ASC). For more information about SCSI sense codes, refer to:
http://sunsolve.sun.com/handbook_pub/Systems/Sun4/TrDISK_SCSI_Sense_Codes.html




[1116] CHL:_ ID:_ SCSI Drive ALERT: Block Reassignment Failed - _ (_)

[1117] CHL:_ ID:_ SCSI Drive ALERT: Block Successfully Reassigned - _ (_)

[1118] CHL:_ ID:_ SCSI Drive ALERT: Aborted Command (_)

[1142] SMART-CH:_ ID:_ Predictable Failure Detected (TEST)

[1142] SMART-CH:_ ID:_ Predictable Failure Detected

[1142] SMART-CH:_ ID:_ Predictable Failure Detected-Starting Clone

[1142] SMART-CH:_ ID:_ Predictable Failure Detected-Clone Failed

Notifications

[11c1] CHL:_ ID:_ SCSI Drive NOTICE: Scan scsi drive Successful


SCSI Channel Events

SCSI channel event messages include:

Alerts

[113f] CHL:_ ALERT: Redundant Loop Connection Error Detected on ID:_

[113f] CHL:_ SCSI Drive Channel ALERT: SCSI Channel Failure

[113f] CHL:_ ALERT: Fibre Channel Loop Failure Detected

[113f] CHL:_ ALERT: Redundant Loop for Chl:_ Failure Detected

[113f] CHL:_ ALERT: Redundant Path for Chl:_ ID:_ Expected but Not Found

[113f] CHL:_ ID:_ ALERT: Redundant Path for Chl:_ ID:_ Failure Detected

Notifications

[113f] CHL:_ NOTICE: Fibre Channel Loop Connection Restored

[113f] CHL:_ ID:_ NOTICE: Redundant Path for Chl:_ ID:_ Restored


Logical Drive Events

Logical drive event messages include:

Alerts

[2101] LG: <NA/Logical Drive Index> Logical Drive ALERT: CHL:_ ID:_ SCSI Drive Failure

[2103] LG:_ Logical Drive ALERT: Rebuild Failed

[2106] LG:_ Logical Drive ALERT: Add SCSI Drive Operation Failed

[2102] LG:_ Logical Drive ALERT: Initialization Failed

[2104] LG:_ Logical Drive ALERT: Parity Regeneration Failed

[2105] LG:_ Logical Drive ALERT: Expansion Failed

[2111] LG:_ Logical Drive ALERT: CHL:_ ID:_ Clone Failed

Notifications

[2181] LG:_ Logical Drive NOTICE: Starting Initialization

[2182] Initialization of Logical Drive _ Completed

[2183] LG:_ Logical Drive NOTICE: Starting Rebuild

[2184] Rebuild of Logical Drive _ Completed

[2185] LG:_ Logical Drive NOTICE: Starting Parity Regeneration

[2186] Parity Regeneration of Logical Drive _ Completed

[2187] LG:_ Logical Drive NOTICE: Starting Expansion

[2188] Expansion of Logical Drive _ Completed

[2189] LG:_ Logical Drive NOTICE: Starting Add SCSI Drive Operation

[218a] Add SCSI Drive to Logical Drive _ Completed

[218b] LG:_ Logical Drive NOTICE: Add SCSI Drive Operation Paused

[218c] LG:_ Logical Drive NOTICE: Continue Add SCSI Drive Operation

[21a1] LG:_ Logical Drive NOTICE: CHL:_ ID:_ Starting Clone

[21a2] LG:_ Logical Drive NOTICE: CHL:_ ID:_ Clone Completed


General Target Alerts

General target alert messages include:

SAF-TE Device

[3f21] SAF-TE Device (_) ALERT: Power Supply Failure Detected (_)

[3f22] SAF-TE Device (_) ALERT: Cooling Fan Not Installed (_)

[3f22] SAF-TE Device (_) ALERT: Cooling Fan Failure Detected (_)

[3f23] SAF-TE Device (_) ALERT: Elevated Temperature Alert (_)

[3f24] SAF-TE Device (_) ALERT: UPS Power Failure Detected (_)

Controller On-Board

[3f23] Peripheral Device ALERT: CPU Temperature <high/low threshold> Temperature Detected (_._C)

[3f23] Peripheral Device ALERT: Board1 Temperature <high/low threshold> Temperature Detected (_._C)

[3f22] Peripheral Device ALERT: Controller FAN _ Not Present or Failure Detected

[3f22] Peripheral Device ALERT: Controller FAN _ <high/low threshold> Speed Detected (_RPM)

[3f21] Peripheral Device ALERT: +3.3V <upper/lower threshold> Voltage Detected (_)

[3f21] Peripheral Device ALERT: +5V <upper/lower threshold> Voltage Detected (_)

[3f21] Peripheral Device ALERT: +12V <upper/lower threshold> Voltage Detected (_)

I2C Device

[3f23] Peripheral Device ALERT: Temperature Sensor _ Failure Detected

[3f23] Peripheral Device ALERT: Temperature Sensor _ Not Present

[3f23] Peripheral Device ALERT: <high/low threshold> Temperature _ Detected (_(F/C)]

[3f22] Peripheral Device ALERT: FAN _ Failure Detected

[3f22] Peripheral Device ALERT: FAN _ Not Present

[3f22] Peripheral Device ALERT: <high/low threshold> FAN _ Speed Detected (_ RPM)

[3f21] Peripheral Device ALERT: Power Supply _ Failure Detected

[3f21] Peripheral Device ALERT: Power Supply _ Not Present

[3f21] Peripheral Device ALERT: <high/low threshold> Power Supply _ Voltage Detected (_)

[3f24] Peripheral Device ALERT: UPS _ AC Power Failure Detected

[3f24] Peripheral Device ALERT: UPS _ Battery Failure Detected

SES Devices

[3f21] SES (C_ I_) Power Supply _: <Vendor descriptor strings/Device Not Supported>!

[3f21] SES (C_ I_) Power Supply _: <Vendor descriptor strings/Device Not Installed>!

[3f21] SES (C_ I_) Power Supply _: <Vendor descriptor strings/Device Unknown Status>!

[3f21] SES (C_ I_) Power Supply _: <Vendor descriptor strings/Device Not Available>!

[3f22] SES (C_ I_) Cooling element _: <Vendor descriptor strings/Device Not Supported>!

[3f22] SES (C_ I_) Cooling element _: <Vendor descriptor strings/Device Not installed>!

[3f22] SES (C_ I_) Cooling element _: <Vendor descriptor strings/Device Unknown Status>!

[3f22] SES (C_ I_) Cooling element _: <Vendor descriptor strings/Device Not Available>!

[3f23] SES (C_ I_) Temperature Sensor _: <Vendor descriptor strings/Device Not Supported>!

[3f23] SES (C_ I_) Temperature Sensor _: <Vendor descriptor strings/Device Not installed>!

[3f23] SES (C_ I_) Temperature Sensor _: <Vendor descriptor strings/Device Unknown Status>!

[3f23] SES (C_ I_) Temperature Sensor _: <Vendor descriptor strings/Device Not Available>!

[3f24] SES (C_ I_) UPS _: <Vendor descriptor strings/Device Not Supported>!

[3f24] SES (C_ I_) UPS _: <Vendor descriptor strings/Device Not installed>!

[3f24] SES (C_ I_) UPS _: <Vendor descriptor strings/Device Unknown Status>!

[3f24] SES (C_ I_) UPS _: <Vendor descriptor strings/Device Not Available>!

[3f21] SES (C_ I_) Voltage sensor _: <Vendor descriptor strings/Device Not Supported>!

[3f21] SES (C_ I_) Voltage sensor _: <Vendor descriptor strings/Device Not installed>!

[3f21] SES (C_ I_) Voltage sensor _: <Vendor descriptor strings/Device Unknown Status>!

[3f21] SES (C_ I_) Voltage sensor _: <Vendor descriptor strings/Device Not Available>!

[3f21] SES (C_ I_) Current sensor _: <Vendor descriptor strings/Device Not Supported>!

[3f21] SES (C_ I_) Current sensor _: <Vendor descriptor strings/Device Not installed>!

[3f21] SES (C_ I_) Current sensor _: <Vendor descriptor strings/Device Unknown Status>!

[3f21] SES (C_ I_) Current sensor _: <Vendor descriptor strings/Device Not Available>!

General Peripheral Device

[3f21] Peripheral Device ALERT: Power Supply Failure Detected

[3f22] Cooling Fan Not Installed

[3f22] Cooling Fan Failure Detected

[3f24] Elevated Temperature Alert

[3f24] UPS Power Failure Detected