A P P E N D I X  B

Parameter Summary Tables

This appendix lists the firmware parameter settings for both the FC and SCSI arrays. You can fine-tune your array by making changes to these settings. It also lists the parameter defaults that you should not change unless advised to do so by technical support.

Topics covered include:


Introducing Default Parameters

Although the factory defaults provide optimized controller operation, you might want to fine-tune your array through minor modifications to the following parameters listed.

Some parameters can be changed only at the initial array configuration; other parameters can be changed at any time. Note the listing of parameters defaults that should not be changed unless directed by technical support.



Note - For customer convenience, these tables apply to both the Sun StorEdge 3310 SCSI array, using firmware version 3.25, and the Sun StorEdge 3510 FC array, using firmware version 3.27.




Basic Default Parameters

These parameters are the primary settings for each array.

TABLE B-1 Logical Drive Parameters (View and Edit Logical Drives)

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Range of Values

Create Logical Drives

  • 1-2 per array.
  • 1-2 spares per array.
  • 1-8 drives per array.

 

 

Change a Logical Drive Controller Assignment

Primary.

 

Secondary.


TABLE B-2 Logical Volume Parameters (View and Edit Logical Volumes)

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Range of Values

Create a Logical Volume

Primary controller.

 

Secondary.

Auto-Assign Global Spare Drive

Disabled.

Disabled.

Enabled.

Disabled.


TABLE B-3 Host LUN Parameters (View and Edit Host LUNs)

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Host LUN IDs

16 IDs per channel maximum in loop mode; 1 ID per channel in point-to-point mode.

Channel 0 ID 40 - primary.

Channel 1 ID 42 - secondary.

Channel 4 ID 44 - primary.

Channel 5 ID 46 - secondary.

2 IDs per channel maximum.

Channel 1 ID 0 - primary.

Channel 1 ID NA- secondary.

Channel 3 ID NA- primary.

Channel 3 ID 1- secondary.


TABLE B-4 SCSI Drive Parameters (View and Edit SCSI Drives)

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Range of Values

FC Drive ID Switch Settings

0

 

0-7


TABLE B-5 SCSI Channel Parameters (View and Edit SCSI Channels)

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Range of Values

Host Channel Settings

0, 1, 4, 5 Host Channels.

1, 3 Host Channels.

Vary by product.

Drive Channel Settings

2 and 3

0 and 2

Vary by product.

Sync Transfer Clock

80 MHz

80 MHz

Do not change this parameter.

2.5 MHz to 80 MHz and Async.

Wide Transfer

Enabled.

Enabled.

Do not change this parameter.

Enabled.

Disabled.

Parity Check

Enabled.

Enabled.

Do not change this parameter.

Disabled.

Enabled.



Default Configuration Parameters

The most important parameter to review are the caching parameters, which impact the block size and optimization performance. Many parameters are optional or unused, depending on the applicable product.

The parameters in the following tables can be set using the View and Edit Configuration Parameters menu:

TABLE B-7 Caching Parameters

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Range of Values

Write-Back Cache

Enabled.

Enabled.

Disabled.

Enabled.

Optimization for Random/Sequential

Sequential

(cannot be changed after the creation of a logical drive).

Sequential

(cannot be changed after the creation of a logical drive).

Sequential or Random.


TABLE B-8 Peripheral Device Type Parameters

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Range of Values

Peripheral Device Type

Enclosure Services Device.

Enclosure Services Device.

No Device Present.

Direct-Access Device.

Sequential-Access Device.

Processor Device.

CD-ROM Device.

Scanner Device.

MO Device.

Storage Array Controller Device.

Enclosure Services Device.

Unknown Device.

Peripheral Device Type Qualifier

Connected.

Connected.

Disconnected.

Connected.

Device Supports Removable Media

Disabled.

Disabled.

Enabled.

Disabled.

LUN Applicability

Undefined LUN-0s Only.

 

Disabled.


TABLE B-9 Host-Side and Drive-Side Parameters

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Range of Values

Host-side SCSI Parameters

Maximum Queued I/O Count

1024 bytes

256 bytes

Auto, or 1-1024 bytes

LUNs per Host SCSI ID

32

32

1 to 32

Maximum Number of Concurrent Host-LUN Connections

1024

128

1 to 1024

Number of Tags Reserved for Each Host-LUN Connection

1024

32

1 to 1024 (FC)

1 to 256 (SCSI)

Host-side SCSI Parameters > Host Cylinder/ Head/ Sector Mapping Parameters

Sector Ranges

Variable.

Variable.

32, 64, 127, 255, Variable sectors.

Head Ranges

Variable.

Variable.

64, 127, 255, Variable heads.

Cylinder Ranges

Variable.

Variable.

1024, 32768, 65536, Variable cylinders.

Host-side SCSI Parameters > Fibre Connection Option

 

 

Loop only

Not applicable

 

FC Range of Values:

Point to point only.

Loop only.

Loop preferred, otherwise point to point.

Drive-side SCSI Parameters

SCSI Motor Spin-Up

Disabled.

Disabled.

Do not change this parameter.

Enabled.

Disabled.

SCSI Reset at Power-Up

Enabled.

Enabled.

Do not change this parameter.

Disabled.

Enabled.

 

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Range of Values

Disk Access Delay Time

15 seconds.

15 seconds.

Do not change this parameter.

None to 75 seconds.

SCSI I/O Timeout

30 seconds.

7 seconds.

500 milliseconds to 30 seconds.

Maximum Tag Count

32

32

1-256 or Disabled.

Periodic Drive Check Time

Disabled.

Disabled.

1/2 to 30 seconds, Disabled.

Periodic SAF-TE/SES Check Time

30 seconds.

30 seconds.

Disabled to 60 seconds.

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Range of Values

Periodic Auto-Detect Failure Drive Swap Check Time

Disabled.

Disabled.

5 to 60 seconds.

Disabled.

Drive Predictable Failure Mode (SMART)

Disabled.

Disabled.

Do not change this parameter.

Detect Only.

Detect and Perpetual Clone.

Detect and Clone + Replace.

Disabled.

Auto-Assign Global Spare Drive

Disabled.

Disabled.

Enabled.

Disabled.


TABLE B-10 Other Configuration Parameters

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Range of Values

Disk Array Parameters

Rebuild Priority

Low.

Low.

Normal, Improved, High, Low.

Verification on Writes

Disabled.

Disabled.

On LD Initialization Writes Disabled.

On LD Rebuild Writes Disabled.

On Normal Drive Writes Disabled.

Redundant Controller Parameters

Secondary Controller RS-232

Disabled.

Disabled.

Enabled.

Disabled.

Remote Redundant Controller

Disabled.

Disabled.

Enabled.

Disabled.

Controller Parameters

Controller Name

Not Set.

Not Set.

Type a name.

LCD Title Display

Controller Logo.

Controller Logo.

Do Not Change this parameter.

Password Validation Timeout

Always Check.

Always Check.

Disable, 1, 2, or 5 minutes.

User-Defined Parameter

FC Default Setting.

SCSI Default Settings

Range of Values

Controller Unique Identifier

Automatically set by the SAF-TE or SES device.

Automatically set by the SAF-TE or SES device.

Type a value.

SDRAM ECC

Enabled.

Enabled.

Do not change this parameter.

DMEP Controller Parameters

Total Usable Memory for DMEP

Disabled.

Disabled.

Type a percentage based on the RAM available from the controller.



Default Peripheral Device Parameters

The following peripheral device parameters are available.

TABLE B-11 Peripheral Device Type Parameters (View and Edit Peripheral Devices)

User-Defined Parameter

FC Default Setting

SCSI Default Settings

Range of Values

Set Peripheral Device Entry

Redundant Controller

Primary.

Primary.

Force primary controller failure.

Force secondary controller failure.

UPS Status

Disabled.

Disabled.

Enabled.

Disabled.

 

Set Peripheral Device Entry > Event Trigger Operations

Temperature exceeds threshold

Not applicable in FC.

Disabled.

Disabled.

Enabled.

Define Peripheral Device Active Signal

 

Low.

Low.

High.

Low.

Controller Peripheral Device Configuration > Voltage and Temperature Parameters

Upper Trigger Threshold for +3.3V Event

Default (3.6V).

Default (3.6V).

Disable, 3.4V - 3.9V.

Lower Trigger Threshold for +3.3V Event

Default (2.9V).

Default (2.9V).

 

Disable, 2.6V - 3.2V.

Upper Trigger Threshold for +5V Event

Default (5.5V).

Default (5.5V).

 

Disable, 5.2V - 6.0V.

Lower Trigger Threshold for +5V Event

Default (4.5V).

Default (4.5V).

 

Disable, 4.0V - 4.8V.

Upper Trigger Threshold for +12V Event

Default (13.2V).

Default (13.2V).

 

Disable, 12.5V - 14.4V.

Lower Trigger Threshold for +12V Event

Default (10.8V).

Default (10.8V).

 

Disable, 9.6V - 11.5V.

Upper Trigger Threshold for CPU Temperature Events

95 (C).

95 (C).

 

Disable, 50-100C.

Lower Trigger Threshold for CPU Temperature Events

Default 0 (C).

Default 0 (C).

 

Disable, 0-20C.

Upper Trigger Threshold for Board Temperature Events

85 (C).

85 (C).

 

Disable, 50-100C.

Lower Trigger Threshold for Board Temperature Events

Default 0 (C).

Default 0 (C).

 

Disable, 0-20C.



Default System Functions

The following system function parameters are available.

TABLE B-12 System Parameters (System Functions)

User-Defined Parameter

FC Default Setting

SCSI Default Setting

Range of Values

Mute Beeper

No.

No.

Yes.

No.

Change Password

No.

No.

Type a password.

No.

Reset Controller

No.

No.

Yes.

No.

Shutdown controller (reserved)

No.

No.

Yes.

No.

Controller Maintenance

Restore NVRAM from disks

No.

No.

Yes.

No.

Save NVRAM to disks

No.

No.

Yes.

No.

Controller Maintenance > Advanced Maintenance Functions

Download Boot Record with Firmware

No.

No.

Yes.

No.



Keeping Specific Parameter Defaults

Default Parameter

Do Not Change these Default Parameters (unless directed by Technical Support)

Fault Management

 

Drive Predictable Failure Mode (SMART)

Disabled on drives.

SDRAM ECC

Enabled.

SCSI Parameters

 

Data Transfer Rate (sync transfer clock)

80 MHz.

Wide Transfer

Enabled.

Parity Check

Enabled.

Spin-Up Parameters

 

SCSI Motor Spin-Up

Disabled.

SCSI Reset at Power-Up

Enabled.

Disk Access Delay Time

15 (none to 75 seconds).