Netra 440 Server Installation Guide
|
|
This appendix gives information on the Netra 440 server LEDs. All of the information in this appendix is related directly to instructions in this guide.
Enclosure Status LEDs
As you install your Netra 440 server, be aware of several enclosure status LED indicators on both the front and back panels. These indicators provide general enclosure status, alert you to system problems, and help you to determine the location of system faults.
At the top left of the server front are three general enclosure status LEDs. Two of these LEDs, the system Service Required LED and the System Activity LED, provide a snapshot of the overall enclosure status. One LED, the Locator LED, helps you to locate a specific system quickly, even though it might be one of many systems in a room. The Locator LED is lit by command from the administrator. For instructions, refer to the Netra 440 Server Diagnostics and Troubleshooting Guide (817-3886-xx).
Other LEDs located on the front of the server work in conjunction with specific fault LED icons. For example, a power supply fault illuminates the associated power supply Service Required LED and the system Service Required LED. Since all front panel status LEDs are powered by the server's 5-volt standby power source, fault LEDs remain lit for any fault condition that results in a system shutdown. Locator, Service Required, and System Activity LEDs are also found at the upper-left corner of the back panel.
The enclosure status LEDs operate as described in the following table.
TABLE B-1 Enclosure Status LEDs
Name
|
Icon
|
Description
|
Locator
|
|
This white LED is lit by Solaris OS command, by Sun Management Center software, or by Sun Remote System Control software, to locate a system. See the Netra 440 Server System Administration Guide for more information
|
Service Required
|
|
This amber LED lights when system hardware or software has detected a system fault. This LED lights for any faults or failures detected in the following areas:
- Motherboard
- CPU/memory module
- DIMM
- Hard drive
- Fan trays
- Power supply
In addition to the system Service Required LED, other fault LEDs might also be lit, depending on the nature of the fault. If the system Service Required LED is lit, check the status of other fault LEDs on the front panel to determine the nature of the fault. See the Netra 440 Server Diagnostics and Troubleshooting Guide for more information.
|
System Active
|
|
This green LED lights when the ALOM detects that Solaris OS is running.
|
Alarm LEDs
The alarm LEDs are located at the front of the system, along the left side of the front cover.
The dry contact alarm card has four LED status indicators that are supported by ALOM. Information about the alarm indicators and dry contact alarm states is provided in TABLE B-2. For more information about alarm indicators, refer to the Sun Advanced Lights Out Manager Software User's Guide for the Netra 440 Server (817-5481-xx). For more information about an API to control the alarm indicators, refer to the Netra 440 Server System Administration Guide (817-3884-xx).
TABLE B-2 Alarm Indicators and Dry Contact Alarm States
Indicator and Relay
Labels
|
Indicator Color
|
Application or Server State
|
Condition or Action
|
System Indicator State
|
Alarm Indicator State
|
Relay
NC
State
|
Relay
NO
State
|
Comments
|
Critical
(Alarm0)
|
Red
|
Server state (Power on/off and
Solaris OS functional/
not functional)
|
No power input.
|
Off
|
Off
|
Closed
|
Open
|
Default state
|
System power off.
|
Off
|
On
|
Closed
|
Open
|
Input power connected
|
System power turns on; Solaris OS not fully loaded.
|
Off
|
On
|
Closed
|
Open
|
Transient state
|
Solaris OS successfully loaded.
|
On
|
Off
|
Open
|
Closed
|
Normal operating state
|
Watchdog timeout.
|
Off
|
On
|
Closed
|
Open
|
Transient state; reboot Solaris OS
|
Solaris OS shutdown initiated by user.
|
Off
|
On
|
Closed
|
Open
|
Transient state
|
Lost input power.
|
Off
|
Off
|
Closed
|
Open
|
Default state
|
System power shutdown initiated by user.
|
Off
|
On
|
Closed
|
Open
|
Transient state
|
Application state
|
User sets Critical alarm on.
|
--
|
On
|
Closed
|
Open
|
Critical fault detected
|
User sets Critical alarm off.2
|
--
|
Off
|
Open
|
Closed
|
Critical fault cleared
|
Major
(Alarm1)
|
Red
|
Application state
|
User sets Major alarm on.2
|
--
|
On
|
Open
|
Closed
|
Major fault detected
|
User sets Major alarm off.2
|
--
|
Off
|
Closed
|
Open
|
Major fault cleared
|
Minor
(Alarm2)
|
Amber
|
Application state
|
User sets Minor alarm on.2
|
--
|
On
|
Open
|
Closed
|
Minor fault detected
|
User sets Minor alarm off.2
|
--
|
Off
|
Closed
|
Open
|
Minor fault cleared
|
User
(Alarm3)
|
Amber
|
Application state
|
User sets User alarm on.2
|
--
|
On
|
Open
|
Closed
|
User fault detected
|
User sets User alarm off.2
|
--
|
Off
|
Closed
|
Open
|
User fault cleared
|
In all cases when the user sets an alarm, a message is displayed on the console. For example, when the critical alarm is set, the following message is displayed on the console:
Note that in some instances when the critical alarm is set, the associated alarm indicator is not lit.
SC Alert: CRITICAL ALARM is set
|
Hard Drive LEDs
The hard drive LEDs are located at the front of the system, behind the front cover, directly above each hard drive.
The following table describes the hard drive LEDs.
TABLE B-3 Hard Drive LEDs
Name
|
Icon
|
Description
|
OK-to-Remove
|
|
This blue LED lights when the hard drive has been taken offline and is safe to remove from the system.
|
Service Required
|
|
Reserved for future use.
|
Activity
|
|
This green LED lights when the system is powered on and a disk is present in the monitored drive slot. This LED flashes slowly during the hard drive hot-swap procedure. It flashes rapidly when the disk is spinning up or down, or during read/write activity.
|
Fan Tray LEDs (0-2)
The fan tray LEDs are located behind the front cover, directly above each fan tray. Note that these LEDs give information only for fan trays 0-2; they do not give information on fan tray 3, located inside the system.
The following table describes the fan tray LEDs.
TABLE B-4 Fan Tray LEDs
Name
|
|
Description
|
Service Required
|
|
This amber LED lights when there is a fault detected with the fan tray. Note that the Service Required LEDs on the front and back panels also light when this occurs.
|
Activity
|
|
This green LED lights when the fan tray is on and operating normally.
|
Power Supply LEDs
The power supply LEDs are located at the rear of the system on each power supply. The following table describes the power supply LEDs.
TABLE B-5 Power Supply LEDs
Name
|
Icon
|
Description
|
OK-to-Remove
|
|
This blue LED lights when it is safe to remove the power supply from the system. This LED is controlled by the software only.
|
Service Required
|
|
This amber LED lights when the power supply's internal circuitry detects a fault. Note that the Service Required LEDs on the front and back panels also light when this occurs.
|
Power OK
|
|
This green LED lights when the power supply is in standby mode or when it is on and outputting regulated power within specified limits.
|
Ethernet Connection LEDs
A set of Ethernet LEDs is located on each Ethernet port. The Ethernet LEDs operate as described in TABLE B-6.
TABLE B-6 Ethernet LEDs
Name
|
Description
|
Link/Activity
|
This green LED lights when a link is established at the particular port with its link partner, and blinks to indicate activity.
|
Speed
|
This amber LED lights when a Gigabit Ethernet connection is established, and is off when a 10/100-Mbps Ethernet connection is established.
|
Network Management Port LED
The network management port has a Link LED that operates as described in TABLE B-7.
TABLE B-7 Network Management Port LED
Name
|
Description
|
Link
|
This green LED is lit when an Ethernet connection is present.
|