A P P E N D I X  A

Connector Pinouts and Switch Settings

This appendix describes the Netra CP2140 board connector pinouts and switch settings.


A.1 CompactPCI Connectors

TABLE A-1 through contain the pinouts of the CompactPCI connectors. The J1 and J2 connector pinouts follow the CompactPCI specification. The J3, J4, and J5 connectors contain semi-custom pinouts.

FIGURE A-1 shows the Netra CP2140 board connectors.

 FIGURE A-1 Netra CP2140 Board Connectors

This is an illustration of a CP2140 board with the J1-J5 connectors marked.

FIGURE A-2 shows the J1 connector.

 FIGURE A-2 J1 Connector

This is a drawing of the J1 connector with pin locations.

TABLE A-1 shows the J1/P1 connector pin assignments

TABLE A-1 J1/P1 Connector Pin Assignments

Pin #

Row Z

Row A

Row B

Row C

Row D

Row E

Row F

25

GND

+5V

REQ64#

ENUM#

+3.3V

+5V

GND

24

GND

AD[1]

+5V

+5Va

AD[0]

ACK64#

GND

23

GND

+3.3V

AD[4]

AD[3]

+5V

AD[2]

GND

22

GND

AD[7]

GND

+3.3V

AD[6]

AD[5]

GND

21

GND

+3.3V

AD[9]

AD[8]

M66EN

C/BE[0]#

GND

20

GND

AD[12]

GND

+5Va

AD[11]

AD[10]

GND

19

GND

+3.3V

AD[15]

AD[14]

GND

AD[13]

GND

18

GND

SERR#

GND

+3.3V

PAR

C/BE[1]#

GND

17

GND

+3.3V

IPMB SCL

IPMB SDA

GND

PERR#

GND

16

GND

DEVSEL#

GND

+5Va

STOP#

LOCK#

GND

15

GND

+3.3V

FRAME#

IRDY#

BD_SEL

TRDY#

GND

14

Key

 

 

 

 

 

Key

13

Key

 

 

 

 

 

Key

12

Key

 

 

 

 

 

Key

11

GND

AD[18]

AD[17]

AD[16]

GND

C/BE[2]#

GND

10

GND

AD[21]

GND

+3.3V

AD[20]

AD[19]

GND

9

GND

C/BE[3]#

IDSEL

AD[23]

GND

AD[22]

GND

8

GND

AD[26]

GND

+5Va

AD[25]

AD[24]

GND

7

GND

AD[30]

AD[29]

AD[28]

GND

AD[27]

GND

6

GND

REQ0#

GND

+3.3V

CLK0

AD[31]

GND

5

GND

BRSVP

BRSVP

RST#

GND

GNT0#

GND

4

GND

IPMB_PWR

HEALTHY_out

+5Va

intp

ints

GND

3

GND

INTA#

INTB#

INTC#

+5V

INTD#

GND

2

GND

tck

+5V

tms

tdo

tdi

GND

1

GND

+5V

-12V

trst

+12V

+5V

GND


Note:1. For the Netra CP2140 board V(O/O) is +5V.2. JTAG tck/tms/tdo/tdi/trst and ints/intp not supported on CP2140.
TABLE A-2 Signal Definitions

AD[0..63]:

cPCI interface 64-bit multiplexed address and data bus

INT[A-D]:

cPCI interface interrupt requests

REQ64#:

cPCI interface request 64-bit transfer

ENUM#:

PICMG 2.1 R1.0 Hot-swap signal - provided to inform System Host that a board has been freshly inserted or is about to be extracted

ACK64#:

cPCI interface 64-bit acknowledge transfer

M66EN#:

Routed to IChip2, 66MHz enable - not supported

SERR#:

cPCI interface System Error for reporting address/data parity errors on the special cycle command

PAR:

cPCI interface even Parity across AD[31..0] and C/BE[3..0]

C/BE[0..7]#:

cPCI Bus Command and Byte Enables multiplexed on the same PCI pins

IPMB_SCL:

Independent Platform Management Bus Clock - see cPCI System Management Specification PICMG 2.9 R1.0

IPMB_SDA:

Independent Platform Management Bus Data - see cPCI System Management Specification PICMG 2.9 R1.0

PERR#:

Parity Error used for reporting of data parity errors

DEVSEL#:

cPCI interface signal Device Select.

STOP#:

cPCI interface signal indicates the current device is requesting the master to stop the current transaction

LOCK#:

cPCI interface signal indicates an operation to a bridge that may require multiple transactions to complete - not supported

FRAME#:

cPCI interface signal indicates the beginning and duration of an access

IRDY#:

cPCI interface signal - Initiator Ready indicate s the bus master s ability to complete the current data phase of the transaction

BD_SEL#:

PICMG 2.1 R1.0 Hot-swap signal - pulled up on the CP2140 unit and driven low to enable power on

TRDY#:

cPCI interface signal Target Ready indicates the selected device s ability to complete the current data phase of the transaction

IDSEL:

cPCI interface signal - Initialization Device Select used as a chip select during read and write transactions

REQ[0..7]#:

cPCI interface signal - request indicates to the arbiter that an agent desires use of the cPCI bus.

GNT[0..7]#:

cPCI interface signal - grant indicates to the agent that the access to the bus has been granted.

CLK[0..7]:

Driven by the SBC - provides timing for all transactions

IPMB_PWR:

Battery back-up power - see CompactPCI System Management Specification PICMG 2.9 R1.0

HEALTHY_OUT:

Radial signal used to acknowledge the health of the board -signals that the board is suitable to be released form reset and allowed onto the bus - see PICMG 2.1 R1.0 Hot-swap Specification.

INTP:

Non-cPCI interrupt, legacy IDE - not supported, 1Kohm pullup provided

INTS:

Non-cPCI interrupt legacy IDE - not supported

TCK, TMS, TDO, TDI:

JTAG signals, not supported - unconnected.


 

 

 

 FIGURE A-3 Netra CP2140 Board J2 Connector

This is a drawing of the J2 connector with pin locations.

See for J2/P2 connector pin assignments.

TABLE A-3 J2/P2 Connector Pin Assignments

Pin #

Row Z

Row A

Row B

Row C

Row D

Row E

Row F

22

GND

GA4

GA3

GA2

GA1

GA0

GND

21

GND

CLK6

GND

BRSVP

BRSVP

BD_OFF_OUT

GND

20

GND

CLK5

GND

ALTSYSEN_L

GND

BD_OFF_IN

GND

19

GND

GND

GND

I2C_SDA

I2C_SCK

ALERT

GND

18

GND

BRSVP

BRSVP

BRSVP

GND

BRSVP

GND

17

GND

BRSVP

GND

PRST#

REQ6#

GNT6#

GND

16

GND

BRSVP

BRSVP

DEG#

GND

BRSVP

GND

15

GND

BRSVP

GND

FAL#

REQ5#

GNT5#

GND

14

GND

AD[35]

AD[34]

AD[33]

GND

AD[32]

GND

13

GND

AD[38]

GND

+5Va

AD[37]

AD[36]

GND

12

GND

AD[42]

AD[41]

AD[40]

GND

AD[39]

GND

11

GND

AD[45]

GND

+5Va

AD[44]

AD[43]

GND

10

GND

AD[49]

AD[48]

AD[47]

GND

AD[46]

GND

9

GND

AD[52]

GND

+5Va

AD[51]

AD[50]

GND

8

GND

AD[56]

AD[55]

AD[54]

GND

AD[53]

GND

7

GND

AD[59]

GND

+5Va

AD[58]

AD[57]

GND

6

GND

AD[63]

AD[62]

AD[61]

GND

AD[60]

GND

5

GND

C/BE[5]#

64_EN_L

+5Va

C/BE[4]#

PAR64

GND

4

GND

RSS_L

BRSVP

C/BE[7]#

GND

C/BE[6]#

GND

3

GND

CLK4

GND

GNT3#

REQ4#

GNT4#

GND

2

GND

CLK2

CLK3

SYSEN#

GNT2#

REQ3#

GND

1

GND

CLK1

GND

REQ1#

GNT1#

REQ2#

GND


Note:1. For CP2140 V(I/O) is +5V.
TABLE A-4 Signal Definitions

GA[0..4]:

Geographical Addressing signals for unique slot identification

BRSVP:

Reserve pins - leave unconnected on backplane

BD_OFF_OUT:

Pulse Reset out used for dual host failover - dual host function not supported, leave unconnected on backplane

ALTSYSEN_L:

PICMG Redundant System Slot Spec 2.13 - Alternate System Controller Enable signal - dual host function not supported, leave unconnected on backplane

BD_OFF_IN:

Pulse Reset in used for dual host failover - dual host function not supported, leave unconnected on backplane

I2C_SDA:

In a dual host system, Inter-Host I2C Bus Data - dual host function not supported, leave unconnected on backplane

I2C_SCK:

In a dual host system, Inter-Host I2C Bus Clock - dual host function not supported, leave unconnected on backplane

ALERT:

cPCI System Management Specification PICMG 2.9 R1.0 signal input to the SMC

PRST#:

Backplane Push Button Reset input to the SMC

DEG#, FAL#:

Power Subsystem status signals input to the SMC

64_EN_L:

PICMG Hot-swap Spec 2.1 R1.0 signal - used to designate 64-bit capability for the slot into which the board is plugged

PAR64:

cPCI interface signal even parity bit that protects AD[32..63] and C/ BE[7..4]#

SYSEN#:

System Slot identification, grounded on the cPCI slot so the board can identify installation into the system slot.

RSS#:

PICMG Redundant System Slot Spec 2.13 - Redundant System Slot identification in dual host systems - not supported, leave unconnected on backplane


 

FIGURE A-4 shows the Netra CP2140 Board J3 Connector.

 FIGURE A-4 Netra CP2140 Board J3 Connector

This is a drawing of the J3 connector with pin locations.

TABLE A-5 shows the J3/P3 connector pin assignments.

TABLE A-5 J3/P3 Connector Pin Assignments

Pin #

Row Z

Row A

Row B

Row C

Row D

Row E

Row F

19

GND

PMC-1

PMC-2

PMC-3

PMC-4

PMC-5

GND

18

GND

PMC-6

PMC-7

PMC-8

PMC-9

PMC-10

GND

17

GND

PMC-11

PMC-12

PMC-13

PMC-14

PMC-15

GND

16

GND

PMC-16

PMC-17

PMC-18

PMC-19

PMC-20

GND

15

GND

PMC-21

PMC-22

PMC-23

PMC-24

PMC-25

GND

14

GND

PMC-26

PMC-27

PMC-28

PMC-29

PMC-30

GND

13

GND

PMC-31

PMC-32

PMC-33

PMC-34

PMC-35

GND

12

GND

PMC-36

PMC-37

PMC-38

PMC-39

PMC-40

GND

11

GND

PMC-41

PMC-42

PMC-43

PMC-44

PMC-45

GND

10

GND

PMC-46

PMC-47

PMC-48

PMC-49

PMC-50

GND

9

GND

PMC-51

PMC-52

PMC-53

PMC-54

PMC-55

GND

8

GND

PMC-56

PMC-57

PMC-58

PMC-59

PMC-60

GND

7

GND

PMC-61

PMC-62

PMC-63

PMC-64

VCC

GND

6

GND

BD_SEL_5#

HEALTHY_5#

PCI_RST_5#

BRSVP

BRSVP

GND

5

GND

BD_SEL_4#

HEALTHY_4#

PCI_RST_4#

BRSVP

BRSVP

GND

4

GND

BD_SEL_3#

HEALTHY_3#

PCI_RST_3#

BRSVP

BRSVP

GND

3

GND

BD_SEL_2#

HEALTHY_2#

PCI_RST_2#

PCIB_RST_L

PCI_RST_6#

GND

2

GND

BD_SEL_1#

HEALTHY_1#

PCI_RST_1#

EP_5V

HEALTHY_6#

GND


TABLE A-6 Signal Definitions

PMC[63..0]

PMC/PIM I/O signals

BD_SEL[0..6]#:

PICMG Hot-swap Spec 2.1 R1.0 Radial board select bi-directional signals

HEALTHY[0..6]#:

PICMG Hot-swap Spec 2.1 R1.0 Radial board healthy input signals

PCI_RST[0..6]:

PICMG Hot-swap Spec 2.1 R1.0 Radial PCI reset output signals


 FIGURE A-5 Netra CP2140 Board J4/P4 Connector

This is a drawing of the J4 connector with pin locations.

TABLE A-7 shows the J4/P4 connector pin assignments.

TABLE A-7 J4/P4 Connector Pin Assignments

Pin #

Row Z

Row A

Row B

Row C

Row D

Row E

Row F

25

GND

MIIA_CRS

MIIA_COL

MIIA_MDIO_L

MIIA_TX_ERS

+5V

GND

24

GND

MIIA_RX_DV

MIIA_RX_ER

MIIA_TX_CLKI

GND

BP_MCA_INT_L

GND

23

GND

MIIA_RXD1

MIIA_RXD2

GND

MIIA_RXD3

MII_RX_CLK

GND

22

GND

GND

MIIA_TXD0

MIIA_TX_EN

MIIA_MDC

MIIA_RXD0

GND

21

GND

MIIA_TXD3

GND

MIIA_TXD2

GND

MIIA_TXD1

GND

20

GND

 

 

LOCAL_I2C_INT_L

GND

FR/BK_SEL

GND

19

GND

MIIB_COL

MIIB_MDIO_L

MIIB_TX_ER

 

 

GND

18

GND

MIIB_RX_CLK

MIIB_RX_DV

MIIB_RX_ER

MIIB_TX_CLKI

MIIB_CRS

GND

17

GND

MIIB_RXD0

GND

MIIB_RXD1

MIIB_RXD2

MIIB_RXD3

GND

16

GND

MIIB_TXD1

MIIB_TXD0

MIIB_TX_EN

MIIB_MDC

GND

GND

15

GND

GND

+5V

+5V

MIIB_TXD3

MIIB_TXD2

GND

14

KEY

 

 

 

 

 

KEY

13

KEY

 

 

 

 

 

KEY

12

KEY

 

 

 

 

 

KEY

11

GND

BP_TYPE0

BP_TYPE1

I2C_SDA

GND

GND

GND

10

GND

SMC_TX

SMC_RX

BP_PWROFF

(I2C_pwr)

+12V

GND

9

GND

GND

GND

I2C_SCL

TRM_PWR1

TRM_PWR2

GND

8

GND

SCDPH_L

SCD<15>_L

SCD<14>_L

SCD<13>_L

SCD<12>_L

GND

7

GND

SCD<4>_L

SCD<3>_L

SCD<2>_L

SCD<1>_L

SCD<0>_L

GND

6

GND

GND

SCDPL_L

SCD<7>_L

SCD<6>_L

SCD<5>_L

GND

5

GND

GND

RSV-MCU-use

+5V

+5V

RSV-MCU-use

GND

4

GND

SRST_L

ACK_L

BSY_L

GND

ATN_L

GND

3

GND

I/O_L

REQ_L

C/D_L

SEL_L

MSG_L

GND

2

GND

Term_Disable

SCD<11>_L

SCD<10>_L

SCD<9>_L

SCD<8>_L

GND

1

GND

RSV-MCU-use

RSV-MCU-use

+3.3V

-12V

GPIO1-RSV-MCU-use

GND


Note:1.The PWROFF signal goes active high when OBP power off command is issued.
TABLE A-8 Signal Definitions

BP_MCA_INT_L:

Reserved for MC system use

LOCAL_I2C_INT_L:

I2C interrupt signals for CP2140 I2C devices

BP_TYPE[0..1]:

Intended to indicate backplane type (HA, FHS, Non-HA, etc) - not supported

SMC_TX/RX:

SMC tty signals

BP_PWROFF:

When OS level init 5 is executed - system is halted and this signal asserted logic level high

I2C_PWR:

I2C power for CP2140 local I2C devices

I2C_SCL/SDA:

CP2140 local I2C clock/data


TABLE A-9 MII Signals

MII_RXD<0:3>:

Receive data

MII_TXD<0:3>:

Transmit data

MII_RX_CLK:

Receive clock

MII_TX_CLKI:

Transmit clock

MII_TX_EN:

Transmit enable

MII_CRS:

Carrier sense

MII_COL:

Collision detect

MII_RX_ER:

Receive error

MII_TX_ER:

Transmit error

MII_RX_DV:

Receive frame detect

MII_MDIO:

Transceiver management data (external)


TABLE A-10 SCSI single-ended levels - SCSI-A on J4 and SCSI-B on J5

ATN:

Attention - Active low n BSY: Busy - Active low

C/D:

Command or Data - Active low

I/O:

Input or output data direction

MSG:

Message phase indicator - active low

ACK:

Acknowledge - Active low

SCD<0:15>:

SCSI data lines - Active low

SCDPHSCSI :

parity high byte; provides parity for SCD[8:15] - Active low

SCDPLSCSI:

parity low byte; provides parity for SCD[0:7] - Active low

SEL:

Select - Active low

REQ:

Request - Active low

SRST:

SCSI bus reset - Active low

TRM_PWR:

Termination power for external SCSI terminator


FIGURE A-6 shows the Netra CP2140 Board J5/P5 Connector.

 FIGURE A-6 Netra CP2140 Board J5/P5 Connector

This is a drawing of the J5 connector with pin locations.

TABLE A-11 shows the Netra CP2140 board J5/P5 Connector Pin Assignments.

TABLE A-11 J5/P5 Connector Pin Assignments

Pin #

Row Z

Row A

Row B

Row C

Row D

Row E

Row F

22

GND

BKRST_IN_L

GND

DIAG_L_OC

+5V

BP_XIR_L

GND

21

GND

KBDDAT

KBDCLK

KBDVCC

AUXDATA

AUXCLK

GND

20

GND

+5V

UBS1_P

USB1_N

KBDGND

INT_2#

GND

19

GND

STB_L

GND

VCC

INT_0#

INT_1#

GND

18

GND

AFD_L

USB2_P

USB2_N

GND

+5V

GND

17

GND

PD<2>

INIT_L

PD<1>

ERR

PD<0>

GND

16

GND

PD<6>

PD<5>

PD<4>

PD<3>

SLIN_L

GND

15

GND

SLCT

PE

BUSY_L

ACK_L

PD<7>

GND

14

GND

RTSA

CTSA

RIA

GND

DTRA

GND

13

GND

DCDA

+5V

RXDA

DSRA

TXDA

GND

12

GND

RTSB

CTSB

RIB

+5V

DTRB

GND

11

GND

DCDB

GND

RXDB

DSRB

TXDB

GND

10

GND

TR0_L

WPROT_L

RDATA_L

HDSEL_L

DSKCHG_L

GND

9

GND

MTR1_L

DIR_L

STEP_L

WDATA_L

WGATE_L

GND

8

GND

DRVDENS1

INDEX_L

MTR0_L

DS1_L

DS0_L

GND

7

GND

DRATE0

SC2D<2>_L

SC2D<1>_L

SC2D<0>_L

DRVDENS0

GND

6

GND

SC2D<6>_L

GND

SC2D<5>_L

SC2D<4>_L

SC2D<3>_L

GND

5

GND

SC2D<10>_L

SC2D<9>_L

SC2D<8>_L

SC2DPL_L

SC2D<7>_L

GND

4

GND

SC2D<13>_L

SC2D<12>_L

GND

MSEN0

SC2D<11>_L

GND

3

GND

Term_Disable

SC2DPH_L

SC2D<15>_L

MSEN1

SC2D<14>_L

GND

2

GND

I/O2_L

REQ2_L

C/D2_L

SEL2_L

MSG2_L

GND

1

GND

BKRST_OUT_L

SRST2_L

ACK2_L

BUSY2_L

ATN2_L

GND


TABLE A-12 Miscellaneous

BKRST_IN_L:

Backplane reset input to SMC

BKRST_OUT_L:

Backplane test output from SMC

BP_XIR_L:

Push button reset system input. Active low

DIAG_LOC:

Diagnostic / Alarm output from SMC


TABLE A-13 USB Signals

USB1_P/N:

USB (Universal Serial Bus) signal pair - RIO-A

USB2_P/N:

USB (Universal Serial Bus) signal pair - RIO-B

INT[0..2]:

cPCI interface signal interrupts, not supported


TABLE A-14 Parallel Port

ACK_L:

Pulsed by peripheral to acknowledge data sent

BUSY:

Indicates a printer cannot accept more data

ERR_L:

Peripheral detected an error

PD[7..0]:

Parallel data lines

PE:

Paper end - indicates printer is out of paper

AFD_L:

auto feed - causes printer to line feed

INIT_L:

initializes the peripheral

SLIN_L:

select in - selects the peripheral

STB_L:

data strobe - indicates data is valid

SLCT:

select, peripheral indicates it is selected


TABLE A-15 Serial COM Ports (A and B), RS 232 Levels

CTS:

clear to send

DCD:

Data Carrier Detected

DSR:

Data Set Ready

DTR:

Data Terminal Ready

RI:

Ring Indicator

RTS:

Request to Send

RXD:

Serial Receive Data

TXD:

Serial Transmit Data


TABLE A-16 Floppy Disk Drive, TTL Levels

DSKCHG_L:

indicates the drive door has been opened

DIR_L:

controls direction of the head during step operations

DRATE[0]:

reflects the value of the data transfer but in the DSR or CCR

DRVDENS[1..0]:

disk density select communication in rev1.0, resvd in 1.1 n DS[1..0]: drive selects

HDSEL_L:

selects top or bottom side head

INDEX_L:

indicates the beginning of a track

MSEN[1..0]:

used for sensing density of the media

RDATA_L:

data read

STEP_L:

step, pulses move head in or out

TR0_L:

indicates the is positioned above track 00

WDATA_L:

write data to drive

WGATE_L:

enables head write circuitry of drive

WPROT_L:

indicates a disk is write-protected


TABLE A-17 Keyboard/Auxiliary Device Signals

AUXCLK:

Clock for PS/2 auxiliary device (mouse) - TTL levels, active high

AUXDAT:

Serial data line for PS/2 auxiliary device (mouse) - TTL levels, active high

KBDCLK:

Clock for PC/AT or PS/2 keyboard - TTL levels, active high

KBDDAT:

Serial data line for PC/AT or PS/2 keyboard - TTL levels, active high


 

 

A.1.1 Mini Din 8-Pin Connector

 FIGURE A-7 Serial Connector- Mini Din 8-Pin Front Panel TTYA Diagram

This is a diagram of a mini din 8-pin serial connector.

TABLE A-18 shows the Mini Din 8-pin connector pinouts.

 

TABLE A-18 Serial Mini Din 8-pin Connector Pinouts

Pin

Signal Name

 

Pin

Signal Name

1

FP_SER_A_DTR

 

5

FP_SER_A_RXD

2

FP_SER_A_CTS

 

6

FP_SER_A_RTS

3

FP_SER_A_TXD

 

7

FP_SER_A_DCD

4

FP_SER_A_GND

 

8

GND


A.1.2 RJ45 Connector

The twisted pair Ethernet connector is a RJ45 connector. The controller auto-negotiates to either 10Base-T or 100Base-T. The pinout shown in TABLE A-19 applies to all of the Ethernet.

 FIGURE A-8 RJ45 Ethernet Connector Diagram

This is a diagram of an RJ45 ethernet connector.

TABLE A-19 shows the Netra CP2140 board front panel Ethernet connector.

 
TABLE A-19 Netra CP2140 Board Front Panel Ethernet Connector Pinout

Pin #

Description

1

TXD+

2

TXD-

3

RXD+

4

4T_D3P

5

4T_D3P

6

RXD-

7

4T_D4P

8

4T_D4P


 

A.1.3 PMC Connectors

FIGURE A-9 shows the PMC connectors: J3001, J3002, and J3003.

 FIGURE A-9 J3001-J3003 Connectors

This illustration shows the J3001-3003 connectors on the CP2140 board.

TABLE A-20 shows the connector pinouts for the J3001 connector.

 

TABLE A-20 PMC J3001 Connector Pinouts

Pin

Voltage

 

Pin

Voltage

1

TCK

 

2

-12V

3

GND

 

4

INTA

5

INTB

 

6

INTC

7

BUSMODE1

 

8

+5V

9

INTD

 

10

PCI_RSVD

11

GND

 

12

PCI_RSVD

13

CLK

 

14

GND

15

GND

 

16

GNT

17

REQ

 

18

+5V

19

V(I/O)

 

20

AD31

21

AD28

 

22

AD27

23

AD25

 

24

GND

25

GND

 

26

CBE3

27

AD22

 

28

AD21

29

AD19

 

30

+5V

31

V (IO)

 

32

AD17

33

FRAME

 

34

GND

35

GND

 

36

IRDY

37

DEVSEL

 

38

+5V

39

GND

 

40

LOCK

41

SDONE

 

42

SBO

43

PAR

 

44

GND

45

V (IO)

 

46

AD15

47

AD12

 

48

AD11

49

AD9

 

50

+5V

51

GND

 

52

CBE0

53

AD6

 

54

AD5

55

AD4

 

56

GND

57

V (IO)

 

58

AD3

59

AD2

 

60

AD1

61

AD0

 

62

+5V

63

GND

 

64

REQ64


A.1.4 PMC J3002 Connector

 

TABLE A-21 PMC J3002 Connector Pinouts

Pin

Voltage

 

Pin

Voltage

1

+12V

 

2

TRST

3

TMS

 

4

TD0

5

TD1

 

6

GND

7

GND

 

8

PCI_RSVD

9

PCI_RSVD

 

10

PCI_RSVD

11

BUSMODE2

 

12

+3.3V

13

RST

 

14

BUSMODE3

15

+3.3V

 

16

BUSMODE4

17

PCI_RSVD

 

18

GND

19

AD30

 

20

AD29

21

GND

 

22

AD26

23

AD24

 

24

3.3V

25

IDSEL

 

26

AD23

27

+3.3V

 

28

AD20

29

AD18

 

30

GND

31

AD16

 

32

CBE2

33

GND

 

34

PMC_RSVD

35

TRDY

 

36

+3.3V

37

GND

 

38

STOP

39

PERR

 

40

GND

41

+3.3V

 

42

SERR

43

CBE1

 

44

GND

45

AD14

 

46

AD13

47

GND

 

48

AD10

49

AD8

 

50

+3.3V

51

AD7

 

52

PMC_RSVD

53

+3.3V

 

54

PMC_RSVD

55

PMC_RSVD

 

56

GND

57

PMC_RSVD

 

58

PMC_RSVD

59

GND

 

60

PMC_RSVD

61

ACK64

 

62

+3.3V

63

GND

 

64

PMC_RSVD


A.1.5 PMC J3003 Connector

 

TABLE A-22 PMC J3003 Connector Pinouts

Pin

Voltage

 

Pin

Voltage

1

IO1

 

2

IO2

3

IO3

 

4

IO4

5

IO5

 

6

IO6

7

IO7

 

8

IO8

9

IO9

 

10

IO10

11

IO11

 

12

IO12

13

IO13

 

14

IO14

15

IO15

 

16

IO16

17

IO17

 

18

IO18

19

IO19

 

20

IO20

21

IO21

 

22

IO22

23

IO23

 

24

IO24

25

IO25

 

26

IO26

27

IO27

 

28

IO28

29

IO29

 

30

IO30

31

IO31

 

32

IO32

33

IO33

 

34

IO34

35

IO35

 

36

IO36

37

IO37

 

38

IO38

39

IO39

 

40

IO40

41

IO41

 

42

IO42

43

IO43

 

44

IO44

45

IO45

 

46

IO46

47

IO47

 

48

IO48

49

IO49

 

50

IO50

51

IO51

 

52

IO52

53

IO53

 

54

IO54

55

IO55

 

56

IO56

57

IO57

 

58

IO58

59

IO59

 

60

IO60

61

IO61

 

62

IO62

63

IO63

 

64

IO64


FIGURE A-10 shows the location of memory module connectors J0601 and J0602, respectively.

This illustration shows the memory connectors J0601 and J0602 on the CP2140 board. 

 FIGURE A-10 Memory Module Connectors J0601 and J0602

 


A.2 Memory Module Connector Pinout

TABLE A-23 and TABLE A-24 show the memory module connector 1 and 2 pinouts.

 

TABLE A-23 Memory Module Connector 1 Pinout (Bottom Side)

Pin #

Front Side

Pin #

Front Side

Pin #

Back Side

Pin #

Back Side

99

VDD_3.3V

49

AB3

100

VSS

50

DQ9

97

DQ43

47

AA2

98

DQ0

48

DQ10

95

DQ42

45

VSS

96

DQ1

46

VDD_3.3V

93

DQ41

43

AB2

94

DQ2

44

DQ11

91

VSS

41

AA1

92

VDD_3.3V

42

DQ12

89

DQ40

39

AB1

90

DQ3

40

DQ13

87

DQ35

37

VDD_3.3V

88

DQ4

38

VSS

85

VDD_3.3V

35

AA0

86

VSS

36

DQ14

83

DQ34

33

AB0

84

DQ5

34

DQ15

81

DQ33

31

VSS

82

DQ6

32

VDD_3.3V

79

DQ32

29

CK3

80

DQ7

30

CK1

77

VSS

27

VDD_3.3V

78

VDD_3.3V

28

VSS

75

CK2

25

S1

76

CK0

26

S0

73

VSS

23

S5

74

RAS0

24

S4

71

NC

21

DQ27

72

RAS2

22

DQ16

69

VDD_3.3V

19

DQ26

70

VSS

20

DQ17

67

AA6

17

VSS

68

CAS0

18

VDD_3.3V

65

AB6

15

DQ25

66

CAS2

16

DQ18

63

AA5

13

DQ24

64

WE0

14

DQ19

61

VSS

11

ALERT

62

VDD_3.3V

12

DQ20

59

AB5

9

VDD_3.3V

60

WE2

10

VSS

57

AA4

7

SA2

58

CKE0

8

DQ21

55

AB4

5

SA1

56

CKE2

6

DQ22

53

VDD_3.3V

3

NC

54

VSS

4

DQ23

51

AA3

1

VDD_3.3VI2C

52

DQ8

2

VDD_3.3V


 

TABLE A-24 Memory Module Connector 2 Pinout (Bottom Side)

Pin #

Front Side

Pin #

Front Side

Pin #

Back Side

Pin #

Back Side

99

VSS

49

DQ62

100

VDD_3.3V

50

AB10

97

DQ71

47

DQ61

98

DQ47

48

AA9

95

DQ70

45

VDD_3.3V

96

DQ46

46

VSS

93

DQ69

43

DQ60

94

DQ45

44

AB9

91

VDD_3.3V

41

DQ59

92

VSS

42

AA8

89

DQ68

39

DQ58

90

DQ44

40

AB8

87

DQ67

37

VSS

88

DQ39

38

VDD_3.3V

85

VSS

35

DQ57

86

VDD_3.3V

36

AA7

83

DQ66

33

DQ56

84

DQ38

34

AB7

81

DQ65

31

VDD_3.3V

82

DQ37

32

VSS

79

DQ64

29

CK4

80

DQ36

30

CK6

77

VDD_3.3V

27

VSS

78

VSS

28

VDD_3.3V

75

CK5

25

S3

76

CK7

26

S2

73

RAS1

23

S7

74

BAA1

24

S6

71

RAS3

21

DQ55

72

BAB1

22

DQ31

69

VSS

19

DQ54

70

VDD_3.3V

20

DQ30

67

CAS1

17

VDD_3.3V

68

BAA0

18

VSS

65

CAS3

15

DQ53

66

BAB0

16

DQ29

63

WE1

13

DQ52

64

AA12

14

DQ28

61

VDD_3.3V

11

DQ51

62

VSS

12

LCLK-I

59

WE3

9

VDD_3.3V

60

AB12

10

VSS

57

CKE1

7

DQ50

58

AA11

8

LCLK-O

55

CKE3

5

DQ49

56

AB11

6

SDA

53

VSS

3

DQ48

54

VDD_3.3V

4

SCK

51

DQ63

1

VDD_3.3V

52

AA10

2

VSS



A.3 SMC Switch Settings for HA and Non-HA Systems

The switches on the CP2140 SMC Module serve two purposes:

  • Establish backplane type (HA or non-HA)
  • Select Boot Device (Boot Flash or SMC config block setting)

SW0501.Switch1 is for HA/Non-HA settings and SW0501.Switch2 is for flash device selection based on SMC settings.

A.3.1 Setting Non-HA Systems

If you have a non-HA system, set the SMC module switch settings before powering on the Netra CP2140 board unit.

  • SW0501.Switch1 ---> Closed (switch is set in the direction of the arrow)
  • SW0501.Switch2 ---> Closed (switch is set in direction of arrow)

See FIGURE A-11 for the location of SW0501 on the Netra CP2140 board.

 FIGURE A-11 Setting Switches to Closed Position

This figure of the CP2140 shows a blow-up image of the SW0501 switch set to the closed position.

 FIGURE A-12 SW0501 Position for non-HA Systems

This figure shows the SW0501 switch position for non high availability systems.

A.3.2 Setting HA Systems

If the user has a HA system, set the SMC switch settings before powering on the CP2140 unit as follows:

  • SW0501.Switch1 ---> Open (switch is set opposite to arrow direction)
  • SW0501.Switch2 ---> Closed (switch is set in direction of arrow)

See FIGURE A-13 for location of SW0501.

 FIGURE A-13 Location of SW0501 on SMC Module

This figure of the CP2140 shows a blow-up image of the SW0501 switch set to the closed position.

FIGURE A-14 shows how to set switch positions for HA systems.

 FIGURE A-14 SW0501 Switch Setting for HA Systems

This figure shows the SW0501 switch setting for high availability systems.


A.4 SCSI and Flash Switch Settings

Two sets of switches on the Netra CP2140 board perform two different functions:

  • SW1801 for flash device selection
  • SW2401 for SCSI termination

The positions of these switches determine the flash device selection and SCSI termination. If a switch is moved in the direction of the arrow, it is closed (ON). If a switch is moved in the opposite direction of the arrow, it is open (OFF). FIGURE A-15 shows switches and the switch setting legend.



Note - The default for both the SW2401 and SW1801 switches is Open/Off.



 FIGURE A-15 Switch Setting Legend

This figure shows the switch setting legend for SW1801 and SW2401.

A.4.1 Flash Device Selection Switches

The position of the two SW1801 switches determines the flash device selection on the board. TABLE A-26 describes the flash device selection.

 

TABLE A-25 Flash Device Switch Setting (SW1801)

Position Switch No. 1

Position Switch No. 2

Description

Open

Open

OBP 1 MB boot flash selected (default)

Should never be user adjusted

Closed

Closed

User flash 1 selected

Open

Closed

User flash 1 and 2 selected


A.4.2 SCSI Termination Switches

Four SW2401 SCSI termination switches are located on the board.

The SCSI switches operate independently from each other and can be set to Open or Closed position. FIGURE A-16 shows an example of SCSI termination switch settings.

 FIGURE A-16 SCSI Termination Switch Setting Example

This figure shows the SW2401 SCSI device selection switches.

TABLE A-26 describes the SCSI termination switch setting.

 

TABLE A-26 SCSI Termination Switch Setting (SW2401)

Position

Switch 1

Switch 2

Switch 3

Switch 4

Open

Termination power supplied for SCSI Bus A.

Termination power supplied for SCSI Bus B.

Termination enabled for SCSI Bus A.

Termination enabled for SCSI Bus B.

Closed

Termination power not supplied for SCSI Bus A.

Termination power not supplied for SCSI Bus B.

Termination disabled for SCSI Bus A.

Termination disabled for SCSI Bus B.


See FIGURE A-17 for the location of flash device, SCSI, and SMC FPGA (SW0501) switches.

 FIGURE A-17 SCSI Switch Selections and SMC on the Netra CP2140 Board

This illustration shows the location of the SW2410, SW1801 and the SMC switches on the CP2140 board.