Running linkrac9i
-
On each node, shut down the Oracle service group:
# hagrp -offline oracle_database_grp -sys system_name
-
On one node, run the following command as oracle user to link Oracle with the VERITAS IPC, VCSMM, and ODM libraries:
$ /opt/VRTSvcs/rac/bin/linkrac9i
Note
If the Oracle binaries are on a cluster file system, perform this step on only one node. If the Oracle binaries are on a local file system of each cluster node, run the command to link Oracle with VERITAS libraries on each cluster node.
If your system uses a bundled C compiler or a compiler other than the ANSI C compiler, you can safely ignore such warnings as:
(Bundled) cc: warning 922: "+Oshortdata=8" is unsupported in the bundled compiler, ignored.
Refer to Oracle Metalink Document ID 66442.1 for more information. Search on: 66442.1 FAQ about C Compiler Issues on HP-UX.
-
On each node, start the Oracle service group:
# hagrp -online oracle_database_grp -sys system_name
-
After starting the Oracle instance, confirm Oracle uses the VERITAS libraries. Examine the Oracle alert file, alert_$ORACLE_SID.log, for the following lines:
Oracle instance running with ODM: VERITAS 4.1 ODM Library, Version 1.0
cluster interconnect IPC version:VERITAS IPC 4.1 08:44:27 Apr 20 2005
Note
If Oracle binaries are on a local file system of each cluster node, examine the Oracle alert file on each of the cluster nodes.
|