A P P E N D I X  A

System Specifications

To obtain maximum reliability and performance, install your server into a proper environment and ensure correct configuration as discussed in this chapter.


A.1 Sun Fire V20z Specifications

A.1.1 Sun Fire V20z Physical Specifications


TABLE A-1 Sun Fire V20z Server Physical Specifications

Specification

English

Metric

Width

16.94 in.

430.276 mm

Depth

28 in.

711.2 mm

Height

1.69 in.

42.93 mm

Weight (max.)

35 lbs

15.88 kg


 

A.1.2 Sun Fire V20z Power Specifications


TABLE A-2 Sun Fire V20z Server AC Input Specifications

Specification

Value

Universal AC Input

100 to 240 VAC, 50/60 Hz

Maximum current

7.0 amps


 

A.1.3 Sun Fire V20z Environmental Specifications


TABLE A-3 Sun Fire V20z Server Unit-Level Environmental Specifications

Specification

State

English

Metric

Temperature

Operating

50° to 95° F

10° to 35° C[1]

 

Non-operating

-40° to 149° F

-40° to 65° C

Humidity

Operating

10% to 90% RH at 80. 6° F max. wet bulb (non-condensing)

10% to 90% RH at 27° C max. wet bulb (non-condensing)

 

Non-operating

10% to 90% RH

10% to 90% RH

Altitude

Operating

Up to 9,800 feet

Up to 3,000 meters

 

Non-operating

Up to 39,370 feet

Up to 12,000 meters

Vibration

Operating

.20 G, 5 to 500 Hz sine sweep

 

Shock

Operating

5 G, 11 ms half-sine

 



A.2 Sun Fire V40z Specifications

A.2.1 Sun Fire V40z Physical Specifications


TABLE A-4 Sun Fire V40z Server Physical Specifications

Specification

English

Metric

Width

19 in.

482.60 mm

Depth

28 in.

711.20 mm

Height

5.25 in.

133.35 mm

Weight (max.)

75 lbs

34.0 kg


 

A.2.2 Sun Fire V40z Power Specifications


TABLE A-5 Sun Fire V40z Server AC Input Specifications

Specification

Value

Universal AC Input

100 to 240 VAC, 47/63 Hz

Maximum current

10.0 amps


 

A.2.3 Sun Fire V40z Environmental Specifications


TABLE A-6 Sun Fire V40z Server Unit-Level Environmental Specifications

Specification

State

English

Metric

Temperature

Operating

50° to 95° F

10° to 35° C[2]

 

Non-operating

-40° to 149° F

-40° to 65° C

Humidity

Operating

10% to 90% RH at 80. 6° F max. wet bulb (non-condensing)

10% to 90% RH at 27° C max. wet bulb (non-condensing)

 

Non-operating

10% to 90% RH

10% to 90% RH

Altitude

Operating

Up to 9,800 feet

Up to 3,000 meters

 

Non-operating

Up to 39,370 feet

Up to 12,000 meters

Vibration

Operating

.20 G, 5 to 500 Hz sine sweep

 

Shock

Operating

5 G, 11 ms half-sine

 


 


1 (TableFootnote) The temperature specifications in this table are rated for sea level. For each rise of 300 meters in altitude, the maximum temperature drops by 1° C.