A P P E N D I X  A

Summary of CLI Options and Commands

This appendix contains:

A list of the CLI commands is also available with the help or usage command within the CLI program.

TABLE A-1 Optional Parameters Available With Most Commands

Options

Function

-d, --disk

LVD JBOD enclosure only. selects the disk device name that you specify such as sd31 or c1t0d0 when a JBOD chassis is selected.

-h, --help, --usage

display valid commands

-l, --list

display a list of local or remote devices that the CLI manages, and exits without processing any commands

-n, --no

assumes a no response to any yes/no prompts. Use this option to run scripts without prompting the user

-o, --oob

access the selected device using out-of-band communication (through its network interface) rather than using SCSI commands

-w, --password

specify the password assigned to the array controller

-p, --port

access the selected device out-of-band, similar to the --oob option, but using the specified TCP port number

-v, --version

display program version information

-y, --yes

assumes a yes response to any yes/no prompts. Use this option to run scripts without prompting the user




Note - An "X" in the FC Array or SCSI Array column in the following table indicates the CLI command works with that device.



TABLE A-2 RAID Array Commands

Command / Page Number

Function

FC Array

SCSI Array

about

display program version and copyright info

X

X

check parity

check device parity

X

X

clear events

clear the event log

X

X

configure channel

configure a host or drive channel

X

X

configure global-spare

configure a disk as a global spare

X

X

configure local-spare

configure a disk as a local spare for a specific logical drive

X

X

configure network-interface

set network interface parameters

X

X

configure partition size

configure a logical drive partition of the specified size

X

X

configure partition delete

delete a logical drive partition

X

X

create host-wwn-name

create a Host-ID/WWN name item

X

 

create logical-drive

create a logical drive

X

X

create logical-volume

create a logical volume over the specified LDs

X

X

delete host-wwn-name

delete a Host-ID/WWN name item

X

 

delete logical-drives

delete a logical drive

X

X

delete logical-volumes

delete one or more logical volumes

X

X

download controller-configuration file

download array controller binary configuration

X

X

download controller-firmware

download array controller firmware (optionally w/ hard reset)

X

X

download disk-firmware

download disk drive firmware to internal drives

X

X

download nvram

download nvram file

X

X

download pld-firmware

download enclosure PLD firmware

X

 

download safte-firmware

download enclosure SAFTE firmware

 

X

download ses-firmware

download enclosure SES firmware

X

 

exit

exit the CLI

X

X

fail

fail a controller in a redundant controller pair

X

X

help

display help for commands

X

X

inquiry

displays SCSI INQUIRY data returned by the array controller

X

X

map partition

map an LD or LV partition to a host channel/target/lun

X

X

mute controller

silence the enclosure alarm

X

X

password

specifies the array controller password

X

X

quit

exit the program

X

X

reset controller

reset the array controller

X

X

reset nvram

restore nvram to factory defaults

X

X

select

specify a storage device to monitor or configure

X

X

set cache-policy

set cache write-behind and optimization policy

X

X

set controller-name

set the controller name

X

X

set controller-password

set the controller password

X

X

set drive-parameters

set drive channel parameters

X

X

set host-parameters

set host channel parameters

X

X

set inter-controller-link

enable/disable per-channel inter-controller-link

X

 

set led

specify a name for a disk drive slot in the array enclosure or expansion chassis.

X

X

set password

set the controller password

X

X

set rs232-configuration

set the RS232 interface baud rate

X

X

set unique-identifier

set the subsystem's 6-digit hexadecimal serial number

X

X

show battery-status

display battery information including battery type, manufacturing data, in-service date, expiration date, and status

X

 

show bypass device

display the bypass status of all devices on a specified loop.

X

 

show bypass RAID

display the hardware bypass status of the RAID controllers on Loop A and Loop B.

X

 

show bypass SFP

display the bypass status of all SFPs on a specified loop

X

 

show cache-policy

display cache policy

X

X

show channels

display channel configuration

X

X

show configuration

display the device's configuration

X

X

show controller-name

display controller name

X

X

show disks

display information for array disks

X

X

show disks in a logical drive

display information for array disks in a logical drive

X

X

show drive-parameters

display drive parameters

X

X

show enclosure-status

display the status for all chassis components including the fan, power supply, temperature sensor, and drive slots

 

X

show events

display the controller event log

X

X

show frus

display FRU-ID information

X

X

show host-wwn-names

display all registered HBA WWNs in the controller for host channels

X

 

show host-parameters

display host i/o parameters

X

X

show inquiry-data

display SCSI INQUIRY data for selected device

X

X

show inter-controller-link

display status of inter-controller link on specified channel

X

 

show ip-address

display the controller's IP network address

X

X

show led-status

display the status for the specified disk drive slot in the array enclosure or expansion chassis.

X

X

show logical-drives

display logical drives

X

X

show logical-drives in a logical volume

display information about for all logical drives in a specified logical volume

X

X

show logical-drives initializing

display the progress of the RAID controller initialization

X

X

show logical-drives parity-check

display the parity check progress for a logical drive

X

X

show logical-drives rebuilding

display the rebuilding progress for all logical drives

X

X

show logical-volumes

display logical volumes

X

X

show loop-map

show the FC loop positional map for a given channel.

X

 

show lun-maps

display lun maps for host channels

X

X

show network-parameters

display controller network parameters

X

X

show partitions

display partitions of logical drives

X

X

show pld-revision

display PLD revision of directly-connected FC expansion chassis

X

 

show port-wwn

display host channel FC Port Name WWNs

X

 

show redundancy-mode

display redundancy status

X

X

show rs232-configuration

display serial port configuration

X

X

show safte-devices

display status of SAF-TE devices

 

X

show ses-devices

display status of SES devices

X

 

show unique-identifier

display subsystem 6-digit unique identifier

X

X

shutdown controller

shut down controller (prepare for power off)

X

X

shutdown logical-drive

shut down (force offline) a logical drive

X

X

unconfigure global-spare

unconfigure a global spare drive

X

X

unconfigure local-spare

unconfigure a local spare drive

X

X

unfail

restore (deassert) a failed controller

X

X

unmap partition

unmap a LD or LV partition to a host channel/target/lun

X

X

upload controller-configuration file

upload array controller binary configuration

X

X

upload nvram

upload an nvram file

X

X

version

display program version

X

X




Note - An "X" in the FC JBOD or SCSI JBOD column indicates the CLI command works with that device.



TABLE A-3 JBOD Commands

Command / Page Number

Function

FC JBOD

SCSI JBOD

about

display program version and copyright info

X

X

download pld-firmware

download PLD firmware into the SES microprocessor in a FC JBOD device

X

 

download ses-firmware

download enclosure SES firmware

X

 

exit

exit the CLI

X

X

help

display help for commands

X

X

inquiry

displays SCSI INQUIRY data returned by the array controller

X

X

quit

exit the program

X

X

select

specify a storage device to monitor or configure

X

X

set led

specify a name for a disk drive slot in the array enclosure or expansion chassis.

X

X

show configuration

display the device's configuration

X

X

show enclosure-status

display the status for all chassis components including the fan, power supply, temperature sensor, and drive slots

 

X

show frus

display FRU-ID information

X

X

show inquiry-data

display SCSI INQUIRY data for selected device

X

X

show led-status

display the status for the specified disk drive slot in the array enclosure or expansion chassis.

X

X

show pld-revision

display PLD revision of directly-connected FC expansion chassis

X

 

show safte-devices

display status of SAF-TE devices

 

X

show ses-devices

display status of SES devices

X

 

version

display program version

X

X