Netra 440 Server Product Overview
|
|
This appendix provides the following specifications for the Netra 440 server:
Physical Specifications
TABLE A-1 Physical Specifications, Netra 440 Server
Measure
|
U.S.
|
Metric
|
Width
|
17.32 inches
|
440.0 mm
|
Depth
|
19.5 inches
|
495 mm
|
Height
|
8.75 inches (5 rack units)
|
222 mm
|
Weight (without PCI cards or rack mounts)
|
79.4 lbs
|
36 kg
|
Weight (fully configured with 19-inch
4-post hardmount rack option)
|
81.6 lbs
|
37 kg
|
Electrical SpecificationsAC Operating Power Limits and Ranges
The information in this section applies to the AC version of the Netra 440 server. TABLE A-2 gives AC power source requirements for each power supply in the Netra 440 server, and TABLE A-3 gives AC power source requirements for the Netra 440 server as a whole.
TABLE A-2 AC Operating Power Limits and Ranges for Each Power Supply in the Netra 440 Server
Description
|
Limit or Range
|
Operating input voltage range
|
90 - 264 VAC
|
Operating frequency range
|
47 - 63 Hz
|
Maximum operating input current
|
5.5 A @ 90 VAC
|
Maximum operating input power
|
500 W
|
TABLE A-3 AC Operating Power Limits and Ranges for the Netra 440 Server
Description
|
Limit or Range
|
Operating input voltage range
|
90 - 264 VAC
|
Operating frequency range
|
47 - 63 Hz
|
Maximum operating input current
|
11 A @ 90 VAC
|
Maximum operating input power
|
1000 W
|
Note - The figures for the maximum operating current are provided to help you specify the fusing and cabling you need to deliver power to your equipment. However, these figures represent worst-case scenarios.
|
DC Power Source Requirements
The information in this section applies to the DC version of the Netra 440 server. TABLE A-4 gives DC power source requirements for each power supply in the Netra 440 server, and TABLE A-5 gives DC power source requirements for the Netra 440 server as a whole.
TABLE A-4 DC Operating Power Limits and Ranges for Each Power Supply in the Netra 440 Server
Description
|
Limit or Range
|
Operating input voltage range
|
-40 VDC to -75 VDC
|
Maximum operating input current
|
11.5 A
|
Maximum operating input power
|
450 W
|
TABLE A-5 DC Operating Power Limits and Ranges for the Netra 440 Server
Description
|
Limit or Range
|
Operating input voltage range
|
-40 VDC to -75 VDC
|
Maximum operating input current
|
23 A
|
Maximum operating input power
|
900 W
|
Environmental Specifications
You can operate and store the Netra 440 server safely in the conditions detailed in TABLE A-6.
TABLE A-6 Netra 440 Server Operating and Storage Specifications
Specification
|
Operating
|
Storage
|
Ambient temperature
|
5°C (41°F) to 40°C (104°F)
Short term:
-5°C (23°F) to 55°C (131°F)
|
-40°C (-40°F) to 70°C (158°F)
|
Relative humidity
|
5% to 85% relative humidity, noncondensing
Short term*: 5% to 90% relative humidity, noncondensing, but not to exceed
0.024 kg water/kg dry air
(0.053 lbs. water/2.205 lb. dry air)
|
Up to 93% relative humidity noncondensing,
38°C (100.4°F) max wet bulb
|
Altitude
|
Up to 3000 m (9842.4 ft.)
|
Up to 12000 m (39369.6 ft.)
|
Clearance and Service Access Specifications
Minimum clearances needed for servicing the system are as follows.
Blockage
|
Required Clearance
|
Front of system
|
36 in (91.4 cm)
|
Back of system
|
36 in (91.4 cm)
|