Installing the Netra CP2300 cPSB Board Software |
The following procedures describe how to install the Solaris 8 2/02 operating environment onto the Netra CP2300 cPSB board using the Operating Environment Installation DVD for Use with Solaris 8 2/02 Operating Environment; Only for Netra CP2300, Netra CT 820 (708-0042-11) DVD which is referred to as the Netra CP2300 Installation DVD in this manual. Future supported Solaris operating environment versions require different installation instructions and might require an installation DVD.
This document contains the following sections:
For the latest software installation instructions, download the most current version of the Netra CP2300 board documentation from this web site:
http://www.sun.com/products-n-solutions/hardware/docs/CPU_Boards
Before installing the Solaris operating environment, see TABLE 1 for a list of the installation requirements.
The Netra CP2300 Installation DVD must only be used when installing the Solaris 8 2/02 operating environment on Netra CP2300 boards. By using the Netra CP2300 Installation DVD and the Solaris Media Kit, you install the Solaris operating environment as well as the packages and patches needed to support the Netra CP2300 cPSB board.
Caution - Do not use the Netra CP2300 Installation DVD to install the Solaris software on any platform other than the Netra CP2300 cPSB board. |
For future supported Solaris operating environment versions, you might need to use an installation DVD to install the software. For more information, contact your field application engineer or refer to the latest versions of the Netra CP2300 cPSB board documentation, which can be downloaded from the following web site:
http://www.sun.com/products-n-solutions/hardware/docs/CPU_Boards
For more specific details about installing the Solaris operating environment, refer to the Solaris 8 Installation Guide (806-0955) and the Solaris 8 Advanced Installation Guide (806-0957). These shipped in your Solaris Media Kit and can be viewed on the Solaris documentation web site:
http://docs.sun.com/
The following procedures describe how to install the Solaris operating environment on either a PMC disk or an IDE drive attached to the Netra CP2300 transition card's EIDE connector.
Note - The procedures described in this document should only be used with the Solaris 8 2/02 operating environment. Do not use any other release of the Solaris operating environment. |
Before installing the Solaris operating environment on an IDE drive:
See Preparing for the Solaris Operating Environment Installation for additional requirements.
Caution - This procedure overwrites existing contents on the hard drive(s). Back up all vital data and software before beginning the Solaris installation. |
To Install the Solaris Operating Environment on an IDE Disk Drive |
1. Place the Netra CP2300 Installation DVD in a DVD-ROM drive accessible to the Netra CP2300 board.
2. Halt the system in one of the following ways:
Power on and wait for the OpenBoot PROM bringup. At the ok prompt, skip to Step 3.
When upgrading the Solaris software, the system should be halted gracefully in order to leave existing file systems in a consistent state.
An orderly shutdown can be performed by becoming superuser (also known as root) and using the halt, init 0, or shutdown commands. See the halt(1M), init(1M), and shutdown(1M) man pages for details.
You should now be at the OpenBoot PROM ok prompt.
3. To boot the Netra CP2300 Installation DVD, use the boot command and the complete device path to the DVD-ROM device at the ok prompt.
If you do not know the complete DVD-ROM device path, use the OpenBoot PROM probe-ide-all and devalias commands to find the DVD-ROM device path.
CODE EXAMPLE 1 shows example probe-ide-all command output. The
probe-ide-all command lists the internal and external IDE devices connected to the Netra CP2300 board's IDE interface. In this example, the probe-ide-all command shows that the DVD-ROM drive is connected to the IDE interface as the primary slave device. Note that if you have a PMC disk installed on the Netra CP2300 board, you might see different output from that shown in CODE EXAMPLE 1.
CODE EXAMPLE 2 shows example devalias cdrom command output.
ok devalias cdrom cdrom /pci@1f,0/pci@1,1/ide@d/cdrom@0,0:f |
The devalias cdrom command output lists the full path to the DVD-ROM drive's cdrom device. However, this output is misleading since the probe-ide-all command list the DVD-ROM as a "Primary Slave" device.
The preceding code examples show the full path to the IDE interface to be:
/pci@1f,0/pci@1,1/ide@d/cdrom@0,0:f
The cdrom@x,0:f is the device name and depends on whether the drive was connected as a master or a slave IDE device. For example:
In the preceding examples, the DVD-ROM drive is connected as a slave device, so the full device path to the DVD-ROM drive is:
/pci@1f,0/pci@1,1/ide@d/cdrom@1,0:f
To boot the Netra CP2300 Installation DVD in this example, you would type:
The Netra CP2300 Installation DVD boots and the Solaris mini-os (mini-root) will be loaded into the system memory.
4. After a few minutes, you are asked to select the language you want to use while running the installer. Type the appropriate number for your choice of language.
5. Answer the installation questions when prompted.
The Netra CP2300 Installation DVD loads an installation mini-os software (mini-root) temporarily on one of the disk partitions (usually the swap partition). Near the start of the installation process, you are asked to select the disk where the mini-root software will be loaded.
Caution - The installer overwrites the existing contents on the hard disk. Before beginning Solaris installation, back up all needed data and software. |
The time that it takes for the mini-root to load depends on what you answered in the menus and on the speed of your system. When the mini-root installation is complete, the system automatically boots from the mini-root.
6. Respond to the questions in the Web Start Solaris command-line interface.
You might be asked to supply the following system information:
Note - Refer to the Solaris 8 2/02 installation documentation for more information about answering these questions. You can find these installation documents on the http://docs.sun.com web site. |
7. Review the Confirm Information screen to make sure that all the installation information is correct.
When making changes by way of a dumb terminal interface use the arrow buttons to select your choice. Press the Return key to place a mark in your chosen field. Press the F2 key or ESC-2 keys to confirm your choices.
The Solaris Web Start installation program begins.
8. Respond to the questions displayed in the Web Start installation program.
Set the following preferences before continuing with the installation:
The Netra CP2300 Installation DVD ejects from the DVD-ROM drive.
9. When prompted, insert the Solaris 8 2/02 DVD or the Solaris 8 2/02 Software 1 of 2 CD into your drive, and select OK.
10. Respond to the questions presented by the Web Start installation program.
The questions might cover the following areas:
Caution - You must select the custom installation option or the Netra CP2300 software installation will fail. |
11. Select the correct products to install.
After you have selected the language and locale of the software, the following screen appears, with these options set by default:
a. Deselect item 3, Multilingual Computer Systems Supplement CD, by entering 3 once to select it, then entering 3 again to deselect the option.
Note - Selecting the item 0 and 1 products is optional and not required for this installation. |
After you have deselected item 3, Multilingual Computer Systems Supplement CD, you should see the following screen:
b. Enter 4 to select the Netra Supplement option.
Select which product components to install with the system. Components marked with an [X] will be installed. [ ] 4 Netra Supplement 0.0 MB [ ] 4.0 Netra ct Platform 3.0 18.9 MB |
c. Select 4.0 (Netra ct Platform 3.0).
d. Select n to complete the product installation portion of the software installation.
12. Make the appropriate choices in the remaining screens.
Caution - You must select to install the 64-bit support. The Solaris 64-bit kernel is the only one supported on Netra CP2300 cPSB boards. Do not choose to install the 32-bit kernel only. |
13. When asked to select among the available Solaris software groups, you must select 1 (Entire Group Plus OEM):
14. After selecting the Entire Group Plus OEM group, select 1 to install the default packages.
15. Continue responding to the Web Start installation questions.
Note - You might need to repartition the disk to allocate at least 10 Gbytes of space for the Solaris operating environment and the Netra CP2300 cPSB board software. |
16. When prompted, verify that the software listed by the Web Start installation program is correct, and type y to install the software.
Enter `y` to accept these values and start the installation, or `n` to return to the beginning and make changes (y/n): y |
17. Wait for the Solaris 8 2/02 DVD or Solaris 8 2/02 Software 1 of 2 CD to complete the installation.
This could take an hour or more, depending on the software you chose to install and the speed of your system. If you are using the Solaris CDs for the installation, you might be prompted to insert the Solaris 8 2/02 Software 2 of 2 CD and continue the installation.
18. When the installation completes, select Done at the Installation details screen.
The installation program automatically installs the required Netra CP2300 board software packages and patches.
Launching installer. Please wait... Installing Additional Software |-1%---------------25%---------------50%---------------75%---------------100%| |
19. After the Netra CP2300 board software is installed, select Done to continue the Solaris installation.
The system reboots. If you chose to eject the DVD or CD at the end of the installation, the DVD or CD is ejected and the Web Start application starts.
After you have completed the software installation from the Solaris CDs or DVD, you see the following screen:
20. Place the Netra CP2300 Installation DVD in the DVD-ROM drive again, and select 1 (CD/DVD) to install the remaining supplemental software from that DVD.
21. When the last CD has finished installing the remaining supplemental Netra CP2300 software, select to reboot the system.
The system automatically installs the patches from the DVD and boots using the Solaris release that you just installed.
22. Download and install additional patches.
Refer to the Netra CP2300 cPSB Board Release Notes (817-1741) for the latest information on the patches available for the Netra CP2300 cPSB board. The document can be downloaded from the following web site:
http://www.sun.com/products-n-solutions/hardware/docs/CPU_Boards
Follow the instructions in the "Applying Patches to a Boot Disk" section of the Netra CP2300 cPSB Board Release Notes (817-1741) to download and install the patches.
23. After the patches are installed, reboot the CP23000 cPSB board.
The following procedures describe how to create a network installation server. Before creating a patched network installation server, see Preparing for the Solaris Operating Environment Installation for installation requirements.
To Create a Network Installation Image Using the Solaris 8 2/02 DVD |
Creating a network installation image using the Solaris 8 2/02 DVD is not supported at this time; you must use the Solaris CDs to create a network installation image instead. Go to To Create a Network Installation Image Using the Solaris 8 2/02 CDs for those instructions.
To Create a Network Installation Image Using the Solaris 8 2/02 CDs |
2. Insert the Solaris 8 2/02 Software 1 of 2 CD in a CD-ROM or DVD-ROM drive accessible to the installation server.
3. Change directories to the Tools directory on the Solaris 8 2/02 CD 1 of 2.
4. Run the setup_install_server script to create an install image on the server:
Where image_directory is the directory on the server where you want to create the Solaris 8 2/02 installation image.
5. Change directories to the root directory.
6. Eject the Solaris 8 2/02 Software 1 of 2 CD.
7. Insert the Solaris 8 Software 2 of 2 CD in a CD-ROM or DVD-ROM drive accessible to the installation server.
8. Change directories to the Tools directory on the Solaris 8 2/02 CD 2 of 2.
9. Run the add_to_install_server script to add the Solaris 8 Software 2 of 2 CD software to the install image.
Where image_directory is the Solaris 8 2/02 install image directory.
10. Change directories to the root directory of the CD.
11. Eject the Solaris 8 2/02 Software 2 of 2 CD.
12. Insert the Netra CP2300 Installation DVD into a DVD-ROM drive accessible to the installation server.
13. Change directories to the /cdrom/multi_icd_sol_8_202_sparc_cs/s0 directory.
14. Run the following script to patch the install image:
Where image_directory is the Solaris 8 2/02 installation image directory.
15. Prepare a space for the additional system-specific packages.
You manually apply these system-specific packages later on in this procedure.
a. Create a directory to hold the additional system-specific packages:
Where package_directory is the name of the directory that you are creating to hold these additional system-specific packages.
b. Enter in the following commands to copy the system-specific packages to the directory you just created:
Where package_directory is the name of the directory that you created to hold these additional system-specific packages.
16. Continue to perform the standard Solaris network installation procedure.
17. Once you have completed the standard Solaris network installation procedure, login as superuser on diskfull node on which you just installed Solaris.
18. Manually apply the following packages:
Where install_server is the name of the installation server and package_directory is the name of the directory that you created to hold these additional system-specific packages.
19. Download and install additional patches.
Refer to the Netra CP2300 cPSB Board Release Notes (817-1741) for the latest information on the patches available for the Netra CP2300 cPSB board. The document can be downloaded from the following web site:
http://www.sun.com/products-n-solutions/hardware/docs/CPU_Boards
Follow the instructions in the "Applying Patches to a Boot Disk" section of the Netra CP2300 cPSB Board Release Notes (817-1741) to download and install the patches.
20. After the patches are installed, reboot the CP23000 cPSB board.
Note - If you are installing diskless clients, follow the procedures in Installing Diskless Clients to set up the boot server and to add diskless clients. |
An alternative approach for steps Step 15, Step 17, and Step 18 would be to use a post-installation script on the installation server to automatically add these packages. For more information, see the "Preparing to Install Solaris Software Over the Network" chapter in the Solaris Advanced Installation Guide, which is included in the Solaris Media Kit and can be viewed on the Solaris documentation web site:
http://docs.sun.com
The following procedures describes how to create a boot server for diskless clients and how to add new diskless clients to the patched boot server. For additional instructions on installing diskless clients, refer to the Solaris 8 2/02 documentation, which you can find on the http://docs.sun.com web site.
Note - You must have a root (i.e.; superuser) password on your diskless server to perform the following tasks. |
Note - This procedure sets up a boot server by starting the operating environment services required for diskless clients. Once you have set up the boot server, see To Add a Diskless Client for instructions on adding diskless clients to the boot server. |
1. Prepare a patched network installation server using the Netra CP2300 Installation DVD and the Solaris 8 2/02 Media Kit software.
Follow the procedures in Preparing Network Installations of the Solaris Operating Environment to create a patched network installation server.
2. Verify that the IP addresses for all other network interfaces on the boot server have corresponding hostnames in the hosts database.
3. Log into the network server as superuser and change directories to the /usr/sadm/bin directory.
4. Use the smosservice command to add boot services to the installation server.
Note - The following command is a single long entry. Do not press the Return key until you have typed the entire text string shown in the following command. |
# ./smosservice add -u root -p root_password -- -x mediapath=image_directory -x platform=sparc.sun4u.Solaris_8 -x cluster=SUNWCXall -x locale=locale |
Refer to the smosservice(1M) man page for more information and options.
For example, if the following entries were used for each variable, the command would appear as follows.
5. Place the Netra CP2300 Installation DVD in the DVD-ROM drive again.
6. Create a usr admin file with the following contents for the SUNWctac package:
7. Enter the following command to add the SUNWctac package to the usr area of the boot service.
Note - The following command is a single long entry. Do not press the Return key until you have typed the entire text string shown in the following command. |
# /usr/sbin/pkgadd -S -M -R /export/Solaris_8 -d /cdrom/multi_icd_sol_8_202_sparc_cs/s0/Netra_Supplement/Netra_ct_Platform_3.0/Product-a path_to_usr_admin_file -n SUNWctac |
Where path_to_usr_admin_file is the path to the usr admin file that you created in Step 6.
8. Create a root admin file with the following contents for the SUNWctmgx and SUNW2jdrt packages:
9. Enter the following command to add the SUNW2jdrt package to the clone area.
Note - The following command is a single long entry. Do not press the Return key until you have typed the entire text string shown in the following command. |
# /usr/sbin/pkgadd -S -n -R /export/root/clone/Solaris_8/sun4u -a path_to_root_admin_file -d /cdrom/multi_icd_sol_8_202_sparc_cs/s0/Netra_Supplement/Netra_ct_Platform_3.0/Product SUNW2jdrt |
Where path_to_root_admin_file is the path to the root admin file that you created in Step 8. Answer yes to all questions after entering this command.
Note - You might see several error messages after entering this command. These error messages are extraneous and should be ignored. |
10. Enter the following command to add the SUNWctmgx package to the clone area.
Note - The following command is a single long entry. Do not press the Return key until you have typed the entire text string shown in the following command. |
# /usr/sbin/pkgadd -S -n -R /export/root/clone/Solaris_8/sun4u -a path_to_root_admin_file -d/cdrom/multi_icd_sol_8_202_sparc_cs/s0/Netra_Supplement/Netra_ct_Platform_3.0/Product SUNWctmgx |
Where path_to_root_admin_file is the path to the root admin file that you created in Step 8. Answer yes to all questions after entering this command.
Note - You might see several error messages after entering this command. These error messages are extraneous and should be ignored. |
11. Enter the following commands to copy the SUNW2jdrt package to the template area:
12. Enter the following commands to copy the SUNWctmgx package to the template area.
Note - The command beginning with tar cvf is a single long entry. Do not press the Return key until you have typed the entire text string shown. |
13. Download and install additional patches.
Refer to the Netra CP2300 cPSB Board Release Notes (817-1741) for the latest information on the patches available for the Netra CP2300 cPSB. The document can be downloaded from the following web site:
http://www.sun.com/products-n-solutions/hardware/docs/CPU_Boards/Netra_CP2300
Follow the instructions in the "Applying Patches to a Diskless Service" section of the Netra CP2300 cPSB Board Release Notes (817-1741) to download and install the patches.
14. After the patches are installed, follow the procedure in To Add a Diskless Client.
1. Prepare a patched boot server for the diskless clients.
Follow the steps in To Create a Boot Server for Diskless Clients to create a boot server for the diskless clients.
2. Log into the patched boot server as superuser.
3. Collect the following information for the diskless client you are adding:
4. Change directories to the /usr/sadm/bin directory.
5. Set up the diskless clients.
For each diskless client, type the following command as superuser (root):
Refer to the smdiskless(1m) man page for more information and options.
For example, if the following entries were used for each variable, the command would appear as follows.
You have to type your superuser password again after typing this command. The installation process should take roughly 5 minutes per client and about 15-30 minutes for the operating environment service to install; however, no progress is displayed on screen while the process is running. Do not cancel or kill the process until the process has successfully completed.
You should see messages similar to the following after a few moments, confirming that the command went through successfully the second time:
Login to client_host as user root was successful. Download of com.sun.admin.osservermgr.cli.OsServerMgrCli from client_host was successful. |
Copyright © 2004, Sun Microsystems, Inc. All rights reserved.