Netra 240 Server Service Manual
|
|
This appendix provides the Netra 240 server specifications. This appendix is divided into the following sections:
Physical Specifications
TABLE D-1 Physical Specifications of the Netra 240 Server
Netra 240 Server Dimensions
|
Measurements
|
Height 2 rack units (RU)
|
3.44 inches (87.4 mm)
|
Width without bezel
|
16.73 inches (425 mm)
|
Width with bezel
|
17.4 inches (442 mm)
|
Depth from front bezel to system board connectors
|
19.0 inches (483 mm)
|
Depth to rear of power supply unit handle
|
20.06 inches (509.5 mm)
|
Weight (approximate) with full configuration
(not including PCI cards and mounting brackets)
|
36 lbs (16.33 kg)
|
Weight (approximate) with full configuration
(including PCI cards and mounting brackets)
|
41 lbs (18.6 kg)
|
Environmental Requirements
You can operate and store the system safely in the conditions detailed in TABLE D-2 (DC server) and TABLE D-3 (AC server).
TABLE D-2 DC Server Operating and Storage Specifications
Specification
|
Operating
|
Storage
|
Ambient temperature
|
5°C (41°F) to 40°C (104°F)
Short term:
-5°C (23°F) to 55°C (131°F)
|
-40°C (-40°F) to 70°C (158°F)
|
Relative humidity
|
5% to 85% relative humidity, noncondensing
Short termi: 5% to 90% relative humidity, noncondensing, but not to exceed
0.024 kg water/kg dry air
(0.053 lbs. water/2.205 lb. dry air)
|
Up to 93% relative humidity noncondensing,
38°C (100.4°F) max wet bulb
|
Altitude
|
Up to 3000 m (9842.4 ft.)
|
Up to 12000 m (39369.6 ft.)
|
TABLE D-3 AC Server Operating and Storage Specifications
Specification
|
Operating
|
Storage
|
Ambient temperature
|
0°C (32°F) to 40°C (104°F)
|
-40°C (-40°F) to 70°C (158°F)
|
Relative humidity
|
10% to 90% relative humidity, noncondensing
|
Up to 93% relative humidity, noncondensing,
38°C (100.4°F) max wet bulb
|
Altitude
|
Up to 3000 m (9842.4 ft.)
|
Up to 12000 m (39369.6 ft.)
|
Acoustic Noise Emissions
The acoustic noise emissions on a Netra 240 server are as follows:
- Operating acoustic noise is 7.0 B (LWAd (1B=10dB))
- Idling acoustic noise is 7.0 B (LWAd (1B=10dB))
Declared noise emissions are in accordance with ISO 9296 standards.
Electrical Specifications
TABLE D-4 gives operating power limits for the DC version of the Netra 240 server, and TABLE D-5 provides the limits for the AC version of the server.
TABLE D-4 DC Operating Power Limits and Ranges
Description
|
Limit or Range
|
Operating Input Voltage Range
|
-40 VDC to -75 VDC
|
Maximum Operating Input Current
|
Less than 15 A
|
Maximum Operating Input Power
|
570 W
|
TABLE D-5 AC Operating Power Limits and Ranges
Description
|
Limit or Range
|
Operating Input Voltage Range
|
90 - 264 VAC
|
Operating Frequency Range
|
47 - 63 Hz
|
Maximum Operating Input Current
|
6.1 A @ 90 VAC
|
Maximum Operating Input Power
|
550 W
|
Note - The figures for the maximum operating current are provided to help you specify the fusing and cabling you need to deliver power to your equipment. However, these figures represent worst-case scenarios.
|
NEBS Level 3 Compliance for the DC-Powered Server
Telcordia certified that the DC-powered version of the Netra 240 server meets
NEBS Level 3 requirements per SR-3580, including the appropriate sections of
GR-63-CORE (Network Equipment-Building System Requirements: Physical Protection) and GR-1089-CORE (Electromagnetic Compatibility and Electrical Safety - Generic Criteria for Network Telecommunications Equipment).
|
Caution - To maintain NEBS compliance, the network management (NET MGT) Ethernet port and the RJ-45 serial management (SERIAL MGT) port must use shielded cables and both ends of the shield must be grounded. Refer to the Netra 240 Installation Guide (817-2698) for cabling information.
|