Netra CT 820 Server Installation Guide
|
|
This appendix gives the system specifications for the Netra CT 820 server.
Electrical Specifications
TABLE A-1 DC Input Specifications
Parameter
|
Conditions/Description
|
MIN
|
NOM
|
MAX
|
Units
|
Input Voltage -DC
|
Continuous input range
|
36
|
|
75
|
VDC
|
Hold-up Time
|
From 48 VDC input
|
4
|
|
|
ms
|
Input Current
|
At full rated load; 36 VDC, 48VDC
|
|
7.6, 5.4
|
|
A
|
Input Protection
|
Non-user serviceable, internally-located input line fuse
|
|
|
|
|
Inrush Surge Current
|
Internally limited by thermistor and electronic switch
|
|
|
12
|
A
|
Operating Frequency
|
Switching frequency of main output transformer
|
125
|
|
145
|
KHz
|
Input Transient Protection
|
Varistor
|
|
|
|
|
Environmental Specifications
The Netra CT 820 server is designed for harsh environments. The chassis features sturdy steel and aluminum construction with a corrosion resistant finish.
Due to the modular construction of the system, components could be added that change the system's environmental constraints. Board-level components and power supply modules have their own operating temperature ratings. Refer to component-specific product manuals for operational details that may affect system performance.
TABLE A-2 summarizes the environmental specifications for the Netra CT 820 server. The source of these specifications is NEBS GR-63-CORE. Systems were subjected to these environments and passed all testing.
TABLE A-2 Chassis Environmental Specifications
Parameter
|
Description
|
Temperature - Operating
|
-0° C to 40° C (32° F to 104° F)
|
Temperature - Operating, short-term (per NEBS GR-63-CORE)
|
-5° C to 55° C (23° F to 131° F)
|
Temperature - Non-Operating
|
-40° C to 70° C (-40° F to 158° F)
|
Humidity - Non-Operating
|
90% noncondensing relative humidity at @ 30° C
|
Shock - Unpackaged
|
Up to 110.2 lbs: 2 inch drop
Over 110.2 lbs: 1 inch drop
|
Shock - Packaged
|
< 450 lbs: 11.8 inch drop (category B, palletized)
|
Vibration - Unpackaged
|
5 Hz to 100 Hz, at 0.1 g sine
|
Vibration - Packaged
|
5 to 100 Hz at 0.5 g sine and 100 to 500 Hz at 1.5 g sine
|
Netra CT 820 Server Installation Guide
|
817-2641-11
|
|
Copyright © 2004, Sun Microsystems, Inc. All rights reserved.