C H A P T E R 3 |
Configuring Driver Parameters |
This chapter describes how to configure the vca device driver parameters used by both the Sun Crypto Accelerator 4000 UTP and MMF Ethernet adapters. This chapter contains the following sections:
The vca device driver controls the Sun Crypto Accelerator 4000 UTP and MMF Ethernet devices. The vca driver is attached to the UNIX pci name property pci108e,3de8 for the Sun Crypto Accelerator 4000 (108e is the vendor ID and 3de8 is the PCI device ID).
You can manually configure the vca device driver parameters to customize each Sun Crypto Accelerator 4000 device in your system. This section provides an overview of the capabilities of the Sun Crypto Accelerator 4000 Ethernet device used in the board, lists the available vca device driver parameters, and describes how to configure these parameters.
The Sun Crypto Accelerator 4000 Ethernet UTP and MMF PCI adapters are capable of the operating speeds and modes listed in Setting Autonegotiation or Forced Mode. By default, the vca device operates in autonegotiation mode with the remote end of the link (link partner) to select a common mode of operation for the speed, duplex, and link-clock parameters. The link-clock parameter is applicable only if the board is operating at a 1000 Mbps. The vca device can also be configured to operate in forced mode for each of these parameters.
Caution - To establish a proper link, both link partners must operate in either autonegotiation or forced mode for each of the speed, duplex, and link-clock (1000 Mbps only) parameters. If both link partners are not operating in the same mode for each of these parameters, network errors will occur. See Enabling Autonegotiation or Forced Mode for Link Parameters With the OpenBoot PROM. |
TABLE 3-1 describes the parameters and settings for the vca device driver.
The following parameters determine the transmit and receive speed and duplex link parameters to be advertised by the vca driver to its link partner. TABLE 3-2 describes the operational mode parameters and their default values.
The Sun Crypto Accelerator 4000 UTP adapter advertised link parameters are different from those of the Sun Crypto Accelerator 4000 MMF adapter as shown in TABLE 3-2.
If all of the previous parameters are set to 1, autonegotiation will use the highest speed possible. If all of the previous parameters are set to 0, you will receive the following error message:
NOTICE: Last setting will leave vca0 with no link capabilities. WARNING: vca0: Restoring previous setting. |
The vca device is capable of sourcing (transmitting) and terminating (receiving) pause frames conforming to the IEEE 802.3x Frame Based Link Level Flow Control Protocol. In response to received flow control frames, the vca device is capable of reducing its transmit rate. Alternately, the vca device is capable of sourcing flow control frames, requesting the link partner to reduce its transmit rate if the link partner supports this feature. By default, the driver advertises both transmit and receive pause capability during autonegotiation.
TABLE 3-3 provides flow control keywords and describes their function.
For Gigabit links, this parameter determines the link-master. Generally, switches are enabled as a link master; in which case, this parameter can remain unchanged. If this is not the case, then the link-master parameter can be used to enable the vca device as a link master.
The vca device supports a programmable mode called enable-ipg0.
Before transmitting a packet with enable-ipg0 enabled (default), the vca device adds an additional time delay. This delay, set by the ipg0 parameter, is in addition to the delay set by the ipg1 and ipg2 parameters. The additional ipg0 delay reduces collisions.
If enable-ipg0 is disabled, the value of ipg0 is ignored and no additional delay is set. Only the delays set by ipg1 and ipg2 will be used. Disable enable-ipg0 if other systems keep sending a large number of continuous packets. Systems that have enable-ipg0 enabled might not have enough time on the network. You can add the additional delay by setting the ipg0 parameter from 0 to 255, which is the media byte time delay. TABLE 3-5 defines the enable-ipg0 and ipg0 parameters.
The additional time delay (or gap) before transmitting a packet (after receiving the packet) (Default=8) |
The vca device supports the programmable interpacket gap parameters (IPG) ipg1 and ipg2. The total IPG is the sum of ipg1 and ipg2. The total IPG is 0.096 microseconds for the link speed of 1000 Mbps.
TABLE 3-6 lists the default values and allowable values for the IPG parameters.
By default, the driver sets ipg1 to 8-byte time and ipg2 to 4-byte time, which are the standard values. (Byte time is the time it takes to transmit one byte on the link, with a link speed of 1000 Mbps.)
If your network has systems that use longer IPG (the sum of ipg1 and ipg2), and if those machines seem to be slow in accessing the network, increase the values of ipg1 and ipg2 to match the longer IPGs of other machines.
TABLE 3-7 describes the receive interrupt blanking values.
These parameters provide the ability to drop packets based on the fullness of the receive FIFO. By default, this feature is disabled. When FIFO occupancy reaches a specific range, packets are dropped according to the preset probability. The probability should increase when the FIFO level increases. Control packets are never dropped and are not counted in the statistics.
These parameters allow you to modify PCI interface features to gain better PCI interperformance for a given application.
You can set the vca device driver parameters in two ways:
If you use the ndd utility, the parameters are valid only until you reboot the system. This method is good for testing parameter settings.
To set parameters so they remain in effect after you reboot the system, create a
/kernel/drv/vca.conf file and add parameter values to this file when you need to set a particular parameter for a device in the system. See To Set Driver Parameters Using a vca.conf File for details.
Use the ndd utility to configure parameters that are valid until you reboot the system.
The following sections describe how you can use the vca driver and the ndd utility to modify (with the -set option) or display (without the -set option) the parameters for each vca device.
Before you use the ndd utility to get or set a parameter for a vca device, you must specify the device instance for the utility.
1. Check the /etc/path_to_inst file to identify the instance number associated with a particular device. Refer to the online manual pages for path_to_inst(4).
# grep vca /etc/path_to_inst "/pci@8,600000/network@1" 0 "vca" "/pci@8,700000/network@1" 1 "vca" |
In the previous example, the three Sun Crypto Accelerator 4000 Ethernet instances are from the installed adapters. The instance numbers are 0 and 1.
2. Use the instance number to select the device.
# ndd -set /dev/vcaN |
Note - In the examples in this user's guide, N represents the instance number of the device. |
The device remains selected until you change the selection.
You can use the ndd utility in two modes:
In noninteractive mode, you invoke the utility to execute a specific command. Once the command is executed, you exit the utility. In interactive mode, you can use the utility to get or set more than one parameter value. Refer to the ndd(1M) online manual page for more information.
This section describes how to modify and display parameter values.
To modify a parameter value, use the -set option.
If you invoke the ndd utility with the -set option, the utility passes value, which must be specified to the named /dev/vca driver instance, and assigns it to the parameter:
# ndd -set /dev/vcaN parameter value |
When you change any adv parameter, a message similar to the following appears:
- link up 1000 Mbps half duplex |
To display the value of a parameter, specify the parameter name and omit the value.
When you omit the -set option, a query operation is assumed and the utility queries the named driver instance, retrieves the value associated with the specified parameter, and prints it:
# ndd /dev/vcaN parameter |
To modify a parameter value in interactive mode, specify ndd /dev/vca, as shown below.
The ndd utility then prompts you for the name of the parameter:
# ndd /dev/vcaN name to get/set? (Enter the parameter name or ? to view all parameters) |
After typing the parameter name, the ndd utility prompts you for the parameter value (see TABLE 3-1 through TABLE 3-9).
To list all the parameters supported by the vca driver, type ndd /dev/vca.
(See TABLE 3-1 through TABLE 3-9 for parameter descriptions.)
The following link parameters can be set to operate in either autonegotiation or forced mode:
By default, autonegotiation mode is enabled for these link parameters. When either of these parameters are in autonegotiation mode, the vca device communicates with the link partner to negotiate a compatible value and flow control capability. When a value other than auto is set for either of these parameters, no negotiation occurs and the link parameter is configured in forced mode. In forced mode, the value for the speed parameter must match between link partners. See Enabling Autonegotiation or Forced Mode for Link Parameters With the OpenBoot PROM.
If your network equipment does not support autonegotiation, or if you want to force your network speed, duplex, or link-clock parameters, you can disable the autonegotiation mode on the vca device.
1. Set the following driver parameters to the values that are described in the documentation delivered with your link partner device (for example, a switch):
See TABLE 3-2 for the descriptions and possible values of these parameters.
2. Set the adv-autoneg-cap parameter to 0.
# ndd -set /dev/vcaN adv-autoneg-cap 0 |
When you change any ndd link parameter, a message similar to the following appears:
link up 1000 Mbps half duplex |
Note - If you disable autonegotiation, you must enable the speed, duplex, and link-clock (1000 Mbps only) parameters to operate in forced mode. For instructions, see Enabling Autonegotiation or Forced Mode for Link Parameters With the OpenBoot PROM. |
You can also specify the driver parameter properties by adding entries to the vca.conf file in the /kernel/drv directory. The parameter names are the same names listed in Driver Parameter Values and Definitions.
Caution - Do not remove any of the default entries in the /kernel/drv/vca.conf file. |
The online manual pages for prtconf(1) and driver.conf(4) include additional details. The next procedure shows an example of setting parameters in a vca.conf file.
Variables defined in the previous section apply to known devices in the system. To set a variable for a Sun Crypto Accelerator 4000 board with the vca.conf file, you must know the following three pieces of information for the device: device name, device parent, and device unit address.
1. Obtain the hardware path names for the vca devices in the device tree.
a. Check the /etc/driver_aliases file to identify the name associated with a particular device.
# grep vca /etc/driver_aliases vca "pci108e,3de8" |
In the previous example, the device name associated with the Sun Crypto Accelerator 4000 software driver (vca) is "pci108e,3de8".
b. Locate the device parent name and device unit address in the
/etc/path_to_inst file.
Refer to the online manual pages for path_to_inst(4).
# grep vca /etc/path_to_inst "/pci@8,600000/network@1" 0 "vca" "/pci@8,700000/network@1" 1 "vca" |
In the previous example, there are three columns of output: device path name, instance number, and software driver name.
The device path name in the first line of the previous example is "/pci@8,600000/network@1". Device path names are made up of three parts: device parent name, device node name, and device unit address. See TABLE 3-10.
To identify a PCI device unambiguously in the vca.conf file, use the entire device path name (parent name, node name, and the unit address) for the device. Refer to the pci(4) online manual page for more information about the PCI device specification.
2. Set the parameters for the above devices in the /kernel/drv/vca.conf file.
name="pci108e,3de8" parent="/pci@8,700000" unit-address="1" adv-autoneg-cap=0; |
4. Save and close all files and programs, and exit the windowing system.
5. Shut down and reboot the system.
If you omit the device path name (parent name, node name, and the unit address), the variable is set for all instances of all Sun Crypto Accelerator 4000 Ethernet devices.
To Set Parameters for All Sun Crypto Accelerator 4000 vca Devices With the vca.conf File |
1. Add a line in the vca.conf file to change the value of a parameter for all instances by entering parameter=value;.
The following example sets the adv-autoneg-cap parameter to 1 for all instances of all Sun Crypto Accelerator 4000 Ethernet devices:
adv-autoneg-cap=1; |
The following is an example vca.conf file:
The following parameters can be configured to operate in autonegotiation or forced mode at the OpenBoot PROM (OBP) interface:
To establish a proper link, the speed, duplex, and link-clock (1000 Mbps only) parameters must be configured correctly between the local link and the link partner. Both link partners must operate in either autonegotiation or forced mode for each of the speed, duplex, and link-clock (1000 Mbps only) parameters. A value of auto for any of these parameters configures the link to operate in autonegotiation mode for that parameter. The absence of a parameter at the OBP prompt configures that parameter to have a default value of auto. A value other than auto configures the local link to operate in forced mode for that parameter.
When the local link is operating in autonegotiation mode for the speed and duplex parameters at 100 Mbps and below and both full and half duplexes, then the link partner uses either the 100 Mbps or 10 Mbps speeds with either duplex.
When the speed parameter is operating in forced mode, the value must match the speed value of the link-partner. If the duplex parameter does not match between the local link and the link partner, the link may come up; however, traffic collisions will occur.
When the local link speed parameter is set to autonegotiation and the link partner speed parameter is set to forced, the link may come up depending on whether the speed value can be negotiated between the local link and the link partner. The interface in autonegotiation mode will always try to establish a link (if there is a speed match) at half duplex by default. Because one of the two interfaces is not in autonegotiation mode, the interface in autonegotiation mode detects only the speed parameter; the duplex parameter is not detected. This method is called parallel-detection.
Caution - The establishment of a link with a duplex conflict always leads to traffic collisions. |
For a local link parameter to operate in forced mode, the parameter must have a value other than auto. For example, to establish a forced mode link at 100 Mbps with half duplex, type the following at the OBP prompt:
ok boot net:speed=100,duplex=half |
To establish a forced mode link at 1000 Mbps with half duplex that is a clock master, type the following command at the OBP prompt:
ok boot net:speed=1000,duplex=half,link-clock=master |
To establish a forced mode for a speed of 10 Mbps and an autonegotiation mode for duplex, type the following at the OBP prompt:
ok boot net:speed=10,duplex=auto |
You could also type the following at the OBP prompt to establish the same local link parameters as the previous example:
ok boot net:speed=10 |
Refer to the IEEE 802.3 documentation for further details.
This section describes the statistics presented by the kstat(1M) command.
TABLE 3-12 describes the cryptographic driver statistics.
TABLE 3-13 describes the Ethernet driver statistics.
TABLE 3-14 describes the transmit and receive MAC counters.
The following Ethernet properties (TABLE 3-15) are derived from the intersection of device capabilities and the link partner capabilities.
TABLE 3-15 describes the current Ethernet link properties.
Current pause setting for the link, see Flow Control Parameters |
||
Current pause setting for the link, see Flow Control Parameters |
||
Type of transceiver in use: 1=internal MII,
|
TABLE 3-16 describes the read-only Media Independent Interface (MII) capabilities. These parameters define the capabilities of the hardware. The Gigabit Media Independent Interface (GMII) supports all of the following capabilities.
Local interface full-duplex capability |
||
Local interface half-duplex capability |
||
Local interface full-duplex capability |
||
Local interface half-duplex capability |
||
Local interface full-duplex capability |
||
Local interface half-duplex capability |
||
Local interface flow control capability 0 = Not asymmetric pause capable 1 = Asymmetric pause (from the local device) capable (See Flow Control Parameters) |
||
Local interface flow control capability 0 = Not Symmetric pause capable 1 = Symmetric pause capable (See Flow Control Parameters) |
TABLE 3-17 describes the read-only link partner capabilities.
0 = Not asymmetric pause capable 1 = Asymmetric pause towards link partner capability (See Flow Control Parameters) |
||
0 = Not symmetric pause capable 1 = Symmetric pause capable (See Flow Control Parameters) |
If the link partner is not capable of autonegotiation (when lp-cap-autoneg is 0), the remaining information described in TABLE 3-17 is not relevant and the parameter value is 0.
If the link partner is capable of autonegotiation (when lp-cap-autoneg is 1), then the speed and mode information is displayed when you use autonegotiation and the link partner capabilities.
TABLE 3-18 describes the driver-specific parameters.
As superuser, type the kstat vca:N command:
# kstat vca:N module: vca instance: 0 name: vca0 class: misc |
Note - In the previous example, N is the instance number of the vca device. This number should reflect the instance number of the board for which you are running the kstat command. |
This section describes how to edit the network host files after the adapter has been installed on your system.
After installing the driver software, you must create a hostname.vcaN file for the adapter's Ethernet interface. Note that in the file name hostname.vcaN, N corresponds to the instance number of the vca interface you plan to use. You must also create both an IP address and a host name for its Ethernet interface in the /etc/hosts file.
1. Locate the correct vca interfaces and instance numbers in the /etc/path_to_inst file.
Refer to the online manual pages for path_to_inst(4).
# grep vca /etc/path_to_inst "/pci@8,600000/network@1" 0 "vca" |
The instance number in the previous example is 0.
2. Use the ifconfig(1M) command to set up the adapter's vca interface.
Use the ifconfig command to assign an IP address to the network interface. Type the following at the command line, replacing ip_address with the adapter's IP address:
# ifconfig vcaN plumb ip_address up |
Note - In the examples in this section, N specifies the instance number of the device. |
Refer to the ifconfig(1M) online manual page and the Solaris documentation for more information.
The following example shows the /etc/hostname.vcaN file required for a system named zardoz that has a Sun Crypto Accelerator 4000 board (zardoz-11).
# cat /etc/hostname.hme0 zardoz # cat /etc/hostname.vca0 zardoz-11 |
3. Create an appropriate entry in the /etc/hosts file for each active vca interface.