Netra CP2300 cPSB Board Installation and Technical Reference Manual
|
|
Declaration of Conformity
|
Compliance Model Number:
|
SBD1F
|
Product Family Name:
|
Netra CP2300 Telecom Blade Server
|
EMC
USA--FCC Class A
This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This equipment may not cause harmful interference.
2. This equipment must accept any interference that may cause undesired operation.
European Union
This equipment complies with the following requirements of the EMC Directive 89/336/EEC:
As Telecommunication Network Equipment (TNE) in both Telecom Centers and Other Than Telecom Centers per (as applicable):
|
EN300-386 V.1.3.1 (09-2001) Required Limits:
|
|
EN55022/CISPR22
|
Class A
|
|
EN61000-3-2
|
Pass
|
|
EN61000-3-3
|
Pass
|
|
EN61000-4-2
|
6 kV (Direct), 8 kV (Air)
|
|
EN61000-4-3
|
3 V/m 80-1000MHz, 10 V/m 800-960 MHz, and 1400-2000 MHz
|
|
EN61000-4-4
|
1 kV AC and DC Power Lines, 0.5 kV Signal Lines
|
|
EN61000-4-5
|
2 kV AC Line-Gnd, 1 kV AC Line-Line and Outdoor Signal Lines, 0.5 kV Indoor signal Lines > 10m
|
|
EN61000-4-6
|
3 V
|
|
EN61000-4-11
|
Pass
|
|
|
|
As Information Technology Equipment (ITE) Class A per (as applicable):
|
EN55022:1998/CISPR22:1997
|
Class A
|
EN55024:1998 Required Limits:
|
|
EN61000-4-2
|
4 kV (Direct), 8 kV (Air)
|
|
EN61000-4-3
|
3 V/m
|
|
EN61000-4-4
|
1 kV AC Power Lines, 0.5 kV Signal and DC Power Lines
|
|
EN61000-4-5
|
1 kV AC Line-Line and Outdoor Signal Lines, 2 kV AC Line-Gnd, 0.5 kV DC Power Lines
|
|
EN61000-4-6
|
3 V
|
|
EN61000-4-8
|
1 A/m
|
|
EN61000-4-11
|
Pass
|
EN61000-3-2:1995 + A1, A2, A14
|
Pass
|
EN61000-3-3:1995
|
Pass
|
Safety
This equipment complies with the following requirements of the Low Voltage Directive 73/23/EEC:
EC Type Examination Certificates:
|
|
EN60950:2000, 3rd Edition
|
TÜV Rheinland Certificate No.
|
|
IEC 60950:1999, 3rd Edition
|
CB Scheme Certificate No. US/7056/UL
|
|
Evaluated to all CB Countries
|
|
|
UL 60950, 3rd Edition, CSA C22.2 No. 60950-00
|
File: E138989-A11-UL-1
|
Supplementary Information: This product was tested and complies with all the requirements for the CE Mark.
/S/
|
|
/S/
|
Dennis P. Symanski DATE
Manager, Compliance Engineering
Sun Microsystems, Inc.
4150 Network Circle, MPK15-102
Santa Clara, CA 95054 U.S.A.
Tel: 650-786-3255
Fax: 650-786-3723
|
|
Donald Cameron DATE
Program Manager
Sun Microsystems Scotland, Limited
Blackness Road, Phase 1, Main Bldg
Springfield, EH49 7LR
Scotland, United Kingdom
Tel: +44 1 506 672 395 Fax: +44 1 506 670 011
|
Declaration of Conformity
Compliance Model Number:
|
SBD1R
|
Product Family Name:
|
Netra CP2300 Telecom Blade Server Rear Transition Card (XCP-2300TRN)
|
EMC
USA--FCC Class A
This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1. This equipment may not cause harmful interference.
2. This equipment must accept any interference that may cause undesired operation.
European Union
This equipment complies with the following requirements of the EMC Directive 89/336/EEC:
As Telecommunication Network Equipment (TNE) in both Telecom Centers and Other Than Telecom Centers per (as applicable):
|
EN300-386 V.1.3.1 (09-2001) Required Limits:
|
|
EN55022/CISPR22
|
Class A
|
|
EN61000-3-2
|
Pass
|
|
EN61000-3-3
|
Pass
|
|
EN61000-4-2
|
6 kV (Direct), 8 kV (Air)
|
|
EN61000-4-3
|
3 V/m 80-1000MHz, 10 V/m 800-960 MHz, and 1400-2000 MHz
|
|
EN61000-4-4
|
1 kV AC and DC Power Lines, 0.5 kV Signal Lines
|
|
EN61000-4-5
|
2 kV AC Line-Gnd, 1 kV AC Line-Line and Outdoor Signal Lines, 0.5 kV Indoor signal Lines > 10m
|
|
EN61000-4-6
|
3 V
|
|
EN61000-4-11
|
Pass
|
|
|
|
As Information Technology Equipment (ITE) Class A per (as applicable):
|
EN55022:1998/CISPR22:1997
|
Class A
|
EN55024:1998 Required Limits:
|
|
EN61000-4-2
|
4 kV (Direct), 8 kV (Air)
|
|
EN61000-4-3
|
3 V/m
|
|
EN61000-4-4
|
1 kV AC Power Lines, 0.5 kV Signal and DC Power Lines
|
|
EN61000-4-5
|
1 kV AC Line-Line and Outdoor Signal Lines, 2 kV AC Line-Gnd, 0.5 kV DC Power Lines
|
|
EN61000-4-6
|
3 V
|
|
EN61000-4-8
|
1 A/m
|
|
EN61000-4-11
|
Pass
|
EN61000-3-2:1995 + A1, A2, A14
|
Pass
|
EN61000-3-3:1995
|
Pass
|
Safety
This equipment complies with the following requirements of the Low Voltage Directive 73/23/EEC:
EC Type Examination Certificates:
|
|
EN60950:2000, 3rd Edition
|
TÜV Rheinland Certificate No.
|
|
IEC 60950:1999, 3rd Edition
|
CB Scheme Certificate No. US/7056/UL
|
|
Evaluated to all CB Countries
|
|
|
UL 60950, 3rd Edition, CSA C22.2 No. 60950-00
|
File: E138989-A11-UL-1
|
Supplementary Information: This product was tested and complies with all the requirements for the CE Mark.
/S/
|
|
/S/
|
Dennis P. Symanski DATE
Manager, Compliance Engineering
Sun Microsystems, Inc.
4150 Network Circle, MPK15-102
Santa Clara, CA 95054 U.S.A.
Tel: 650-786-3255
Fax: 650-786-3723
|
|
Donald Cameron DATE
Program Manager
Sun Microsystems Scotland, Limited
Blackness Road, Phase 1, Main Bldg
Springfield, EH49 7LR
Scotland, United Kingdom
Tel: +44 1 506 672 395 Fax: +44 1 506 670 011
|
Netra CP2300 cPSB Board Installation and Technical Reference Manual
|
816-7186-12
|
|
Copyright © 2004, Sun Microsystems, Inc. All rights reserved.