C H A P T E R  35

LOMlite Alarm Test (lomlitetest)

lomlitetest tests the functionality of LOMlite and LOMlite 2 system monitoring, alarms, and lights-out management (LOM) processors currently used in Netratrademark T platforms. This test also tests the legacy TSalarms alarm card used in some Netra t 11xx systems. lomlitetest exercises the hardware and device drivers for the LOMlite, LOMlite 2, or TSalarms device, and tests the system and environmental monitoring functions of the device.

This test is not scalable.



Note - During offline functional testing, messages from the LOM processor are seen on the system console. This is normal and does not indicate a fault.




lomlitetest Requirements


lomlitetest Subtests
TABLE 35-1 lomlitetest Subtests

Subtest

Description

Connection subtest

Run for both LOMlite and TSalarms. Attempts to open the device nodes appropriate to the device being tested.

Passive Read subtest

Attempts to read the available data from the device being tested. Device data is read as follows:

All devices: Alarm state

LOMlite and LOMlite 2:

  • Fault LED state

  • Power supply state

  • Fans state

  • EEPROM event log

LOMlite 2 only:

  • Power supply voltages

  • Enclosure and CPU temperatures

Active Alarms subtest

Reads, inverts, and re-reads each alarm state to ensure change took effect. Resets alarms to original state and checks that the state is correct. In the case of LOMlite and LOMlite 2 devices, reads the EEPROM event log and ensures that the expected events are recorded.

Active Fault LED subtest

Reads, inverts, rereads and resets the state of the fault indicator LED. Checks that the state changes are recorded in the EEPROM event log.



lomlitetest Options

This test has no programmable options unless it is run on a multi-processor system. On single-processor systems, the appropriate subtests are automatically selected depending upon the test mode and the type of device detected or specified on the command line.

FIGURE 35-1 shows the options menu for a multi-processor system. To reach the dialog box below, right-click on the test name in the System Map and select Test Parameter Options. If you do not see this test in the System Map, you might need to expand the collapsed groups, or your system may not include the device appropriate to this test. Refer to the SunVTS User's Guide for more details.

FIGURE 35-1 lomlitetest Test Parameter Options Dialog Box

Screenshot of the lomlitetest Test Parameter Options dialog box.


lomlitetest Test Modes
TABLE 35-2 lomlitetest Supported Test Modes

Test Mode

Description

Connection

Runs the Connection subtest.

Functional

(Offline)

Runs all subtests.



lomlitetest Command-Line Syntax

/opt/SUNWvts/bin/lomlitetest standard_arguments -o dev=lomlite2|lomlite|tsalarms

TABLE 35-3 lomlitetest Command-Line Syntax

Argument

Description

dev=lomlite2|lomlite|tsalarms

Selects the type of device driver to test.