The Netra 20 server has three sets of LEDs that show the status of the system.
System LEDs
The system LEDs are located behind the front fascia, immediately to the right of the ON/STBY switch as you face the unit, as shown in FIGURE 6-1.
Light pipes transmit the Power, System, Alarm1, Alarm2 and Fault LEDs through the fascia and are visible from the front of the system. To view the remaining LEDs, you must lower the front fascia.
The Alarm1, Alarm2, System and Fault LEDs are mirrored on the LOMlite2 card visible from the rear of the system (see LOMlite 2 LEDs).
FIGURE 6-1 Front Panel System LEDs
TABLE 6-1 Front Panel System LED Functions
LED
|
Icon
|
Color
|
Function
|
Power
|
|
Green
|
Illuminated continuously while power is supplied to the system.
|
System
|
SYSTEM
|
Green
|
Off (or reset) during power up procedures and illuminated when UNIX is running and the Alarms driver is installed. This LED is reset by a hardware Watchdog timeout, or whenever the user-defined Alarm3 is asserted.
|
Alarm11
|
ALARM1
|
Amber
|
Illuminated whenever the user-defined Alarm1 is asserted
|
Alarm21
|
ALARM2
|
Amber
|
Illuminated whenever the user-defined Alarm2 is asserted
|
Input A OK
|
DC-A
|
Green
|
Illuminated when the input voltage from feeder A is above 37 V
Off when Input A is below 35 V
Not used in the AC version
|
Input B OK
|
DC-B
|
Green
|
Illuminated when the input voltage from feeder B is above 37 V
Off when Input B is below 35 V
Not used in the AC version
|
Fault1
|
|
Amber
|
Driven by the LOMlite2 module under identified system fault conditions
|
Disk0 Active
|
|
Green
|
Illuminated when Disk0 is active
|
Disk0 OK to Remove2
|
|
Blue
|
Illuminated, in response to a user request, when Disk0 can be removed safely without affecting the system operation
|
Disk0 Fault2
|
|
Amber
|
Illuminated when the system has identified a fault in Disk0
|
Disk1 Active2
|
|
Green
|
Illuminated when Disk1 is active
|
Disk1 OK to Remove2
|
|
Blue
|
Illuminated, in response to a user request, when disk1 can be removed safely without affecting the system operation
|
Disk1 Fault2
|
|
Amber
|
Illuminated when the system has identified a fault in Disk1
|
LOMlite 2 LEDs
The LOMlite2 status LEDs, which mirror the alarm status and power LEDs on the front panel, are located on the rear of the system, between the LOMlite2 DB-15 alarm relay port and RJ45 serial port, as shown in FIGURE 6-2.
TABLE 6-2 LOMlite2 Status LED Functions
LED
|
Legend
|
Color
|
Function
|
Alarm 1
|
1
|
Amber
|
Illuminated when user-defined Alarm 1 is asserted
|
Alarm 2
|
2
|
Amber
|
Illuminated when user-defined Alarm 2 is asserted
|
Fault
|
|
Amber
|
Driven by the LOMlite 2 card and illuminated when a system fault condition exists
|
System
|
SYS
|
Green
|
Illuminated when Solaris is running and the LOMlite2 driver is installed
Off while the system is powering up
Reset by watchdog timeout, assertion of user-defined Alarm 3
|
FIGURE 6-2 LOMLite2 Status LEDs
PSU LEDs
The PSU status LEDs are located at the left hand end of the PSU.
Netra 20 AC System
TABLE 6-3 PSU Status LED Functions (Netra 20 AC System)
LED
|
Icon
|
Color
|
Function
|
AC Input OK
|
|
Green
|
Illuminated when AC is present and above 85 VAC
|
PSOK
|
|
Green
|
Illuminated when output voltages are within operating range
Flashes when PSU is in Standby mode
|
Fail
|
|
Amber
|
Illuminated when PSU is in a Fault condition or has shutdown
Off when PSU is enabled (OK)
Flashes if unit is within 10°C of thermal shutdown
|
FIGURE 6-3 PSU Status LEDs (Netra 20 AC System)
Netra 20 DC System
TABLE 6-4 PSU Status LED Functions (Netra 20 DC System)
LED
|
Icon
|
Color
|
Function
|
Fail
|
|
Amber
|
Illuminated when PSU is in a Fault condition
Off when PSU is not enabled (OK)
Flashes if unit is within 10°C of thermal shutdown or has shutdown
|
PSOK
|
|
Green
|
lluminated when output voltages are within operating range
Flashes when PSU is in Standby mode
|
Input B OK
|
B
|
Green
|
Illuminated when input voltage from feeder B is above 37 V
Off when Input B is below 35 V
|
Input A OK
|
A
|
Green
|
Illuminated when input voltage from feeder A is above 37 V
Off when Input A is below 35 V
|