Declaration of Conformity

Compliance Model Number:

SBD1F

Product Family Name:

Netra CP2300 Telecom Blade Server


EMC

USA--FCC Class A

This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. This equipment may not cause harmful interference.

2. This equipment must accept any interference that may cause undesired operation.

European Union

This equipment complies with the following requirements of the EMC Directive 89/336/EEC:

As Telecommunication Network Equipment (TNE) in both Telecom Centers and Other Than Telecom Centers per (as applicable):

EN300-386 V.1.3.1 (09-2001) Required Limits:

 

EN55022/CISPR22

Class A

 

EN61000-3-2

Pass

 

EN61000-3-3

Pass

 

EN61000-4-2

6 kV (Direct), 8 kV (Air)

 

EN61000-4-3

3 V/m 80-1000MHz, 10 V/m 800-960 MHz, and 1400-2000 MHz

 

EN61000-4-4

1 kV AC and DC Power Lines, 0.5 kV Signal Lines

 

EN61000-4-5

2 kV AC Line-Gnd, 1 kV AC Line-Line and Outdoor Signal Lines, 0.5 kV Indoor signal Lines > 10m

 

EN61000-4-6

3 V

 

EN61000-4-11

Pass

 

 

 

As Information Technology Equipment (ITE) Class A per (as applicable):

EN55022:1998/CISPR22:1997

Class A

EN55024:1998 Required Limits:

 

EN61000-4-2

4 kV (Direct), 8 kV (Air)

 

EN61000-4-3

3 V/m

 

EN61000-4-4

1 kV AC Power Lines, 0.5 kV Signal and DC Power Lines

 

EN61000-4-5

1 kV AC Line-Line and Outdoor Signal Lines, 2 kV AC Line-Gnd, 0.5 kV DC Power Lines

 

EN61000-4-6

3 V

 

EN61000-4-8

1 A/m

 

EN61000-4-11

Pass

EN61000-3-2:1995 + A1, A2, A14

Pass

EN61000-3-3:1995

Pass


Safety

This equipment complies with the following requirements of the Low Voltage Directive 73/23/EEC:

EC Type Examination Certificates:

 

EN60950:2000, 3rd Edition

TÜV Rheinland Certificate No.

 

IEC 60950:2000, 3rd Edition

CB Scheme Certificate No. US/7056/UL

 

Evaluated to all CB Countries

 

 

UL 60950, 3rd Edition, CSA C22.2 No. 60950-00

File: E138989-A11-UL-1


Supplementary Information: This product was tested and complies with all the requirements for the CE Mark.

 

/S/

 

 

 

/S/

Dennis P. Symanski DATE

Manager, Compliance Engineering

Sun Microsystems, Inc.

4150 Network Circle, MPK15-102

Santa Clara, CA 95054 U.S.A.

Tel: 650-786-3255

Fax: 650-786-3723

 

Donald Cameron DATE

Program Manager

Sun Microsystems Scotland, Limited

Blackness Road, Phase 1, Main Bldg

Springfield, EH49 7LR

Scotland, United Kingdom

Tel: +44 1 506 672 395 Fax: +44 1 506 670 011



Declaration of Conformity

Compliance Model Number:

SBD1R

Product Family Name:

Netra CP2300 Telecom Blade Server Rear Transition Card (XCP-2300TRN)


EMC

USA--FCC Class A

This equipment complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

1. This equipment may not cause harmful interference.

2. This equipment must accept any interference that may cause undesired operation.

European Union

This equipment complies with the following requirements of the EMC Directive 89/336/EEC:

As Telecommunication Network Equipment (TNE) in both Telecom Centers and Other Than Telecom Centers per (as applicable):

EN300-386 V.1.3.1 (09-2001) Required Limits:

 

EN55022/CISPR22

Class A

 

EN61000-3-2

Pass

 

EN61000-3-3

Pass

 

EN61000-4-2

6 kV (Direct), 8 kV (Air)

 

EN61000-4-3

3 V/m 80-1000MHz, 10 V/m 800-960 MHz, and 1400-2000 MHz

 

EN61000-4-4

1 kV AC and DC Power Lines, 0.5 kV Signal Lines

 

EN61000-4-5

2 kV AC Line-Gnd, 1 kV AC Line-Line and Outdoor Signal Lines, 0.5 kV Indoor signal Lines > 10m

 

EN61000-4-6

3 V

 

EN61000-4-11

Pass

 

 

 

As Information Technology Equipment (ITE) Class A per (as applicable):

EN55022:1998/CISPR22:1997

Class A

EN55024:1998 Required Limits:

 

EN61000-4-2

4 kV (Direct), 8 kV (Air)

 

EN61000-4-3

3 V/m

 

EN61000-4-4

1 kV AC Power Lines, 0.5 kV Signal and DC Power Lines

 

EN61000-4-5

1 kV AC Line-Line and Outdoor Signal Lines, 2 kV AC Line-Gnd, 0.5 kV DC Power Lines

 

EN61000-4-6

3 V

 

EN61000-4-8

1 A/m

 

EN61000-4-11

Pass

EN61000-3-2:1995 + A1, A2, A14

Pass

EN61000-3-3:1995

Pass


Safety

This equipment complies with the following requirements of the Low Voltage Directive 73/23/EEC:

EC Type Examination Certificates:

 

EN60950:2000, 3rd Edition

TÜV Rheinland Certificate No.

 

IEC 60950:2000, 3rd Edition

CB Scheme Certificate No. US/7056/UL

 

Evaluated to all CB Countries

 

 

UL 60950, 3rd Edition, CSA C22.2 No. 60950-00

File: E138989-A11-UL-1


Supplementary Information: This product was tested and complies with all the requirements for the CE Mark.

 

/S/

 

 

 

/S/

Dennis P. Symanski DATE

Manager, Compliance Engineering

Sun Microsystems, Inc.

4150 Network Circle, MPK15-102

Santa Clara, CA 95054 U.S.A.

Tel: 650-786-3255

Fax: 650-786-3723

 

Donald Cameron DATE

Program Manager

Sun Microsystems Scotland, Limited

Blackness Road, Phase 1, Main Bldg

Springfield, EH49 7LR

Scotland, United Kingdom

Tel: +44 1 506 672 395 Fax: +44 1 506 670 011