Cluster Platform 15K/9960 System Late-Breaking News |
This document contains the late-breaking news for the Cluster Platform 15K/9960 system. These issues were discovered after the production of the documentation. Some of these issues were documented in the Cluster Platform 15K/9960 System Release Notes. They are repeated here with applicable updates for your convenience.
This section contains the known issues after the Cluster Platform 15K/9960 documents were produced.
MPxIO is not supported in this release of the Cluster Platform 15K/9960 software.
For documentation on the Sun StorEdge 9960 storage system, use one of the following sites:
A Sun service engineer must submit a site-planning audit form before the installation occurs. Refer to the following site to submit the form:
This section contains the known issues in the documentation that were found after the production of the documentation.
A task map appears in the preface of the Cluster Platform 15K/9960 System Installation Guide. Disregard that version of the task map, and use the following version.
1. Read all of the Cluster Platform 15K/9960 documentation, Sun Fire 15K documentation, and Sun StorEdge 9960 documentation that was sent with the system.
2. Unpack all of the system crates.
3. Obtain domain A Ethernet address for both cluster nodes (look on the label on the server frame), and save that information in the Cluster Platform 15K/9960 System Site Planning Guide.
4. Verify compliance with all requirements specified in the Cluster Platform 15K/9960 System Site Planning Guide.
5. Cable the system components (consoles, disks, network interfaces), and make sure that the power cables are attached to proper power sources.
6. Connect and configure the terminal concentrator by using a Sun workstation or a laptop PC.
7. Power on the Sun StorEdge 9960.
8. Create and configure the LUNs
The LUNs (that is, the shared storage) must be bound to the appropriate FC-AL links that are attached to the cluster nodes and must be accessible by both cluster nodes.
9. Power on the cluster nodes.
10. Start a console session for the system controllers (that is, SC0 and SC1) for both cluster nodes by using the telnet(1M) command on specific ports of the terminal concentrator.
To access the system controller consoles, use the following commands:
# telnet TC 5002 (SC0 on node 1) # telnet TC 5003 (SC1 on node 1) # telnet TC 5004 (SC0 on node 2) # telnet TC 5005 (SC1 on node 2) |
11. Power on domain A on each cluster node by using the setkeyswitch(1M) command.
Refer to the Sun Fire 15K Installation and De-Installation Guide for instructions on how to power on the domains.
12. Configure the system controllers by using the configuration information in the Cluster Platform 15K/9960 System Site Planning Guide.
13. After the system controllers are booted, verify or re-configure the SMS software on each cluster node.
The following items are pre-configured at the factory and must remain the same:
14. Verify the status and hardware allocation of domain A on each cluster node.
15. Configure the management server.
16. Use the configuration information in the Cluster Platform 15K/9960 System Site Planning Guide to configure the cluster environment on the management server.
17. Log in to the management server as the superuser, and use the ccp(1M) command to display the node console windows.
18. Execute the boot net -s command to bring up the domains in single-user mode.
19. Invoke the format(1M) command and verify the following items:
20. Install the software on the cluster nodes.
ok boot net -s (which was done in Step 18) ok boot net -install |
21. If you chose Solstice DiskSuite 4.2.1 as the volume manager, you must select a quorum device from shared storage (that is, the LUNs) by using the scsetup(1M) command.
22. Configure the NAFO groups using the pnmset(1M) command.
23. Install data services using one of the management server data services repositories.
You can use either of the following repositories:
/net/management_server_name-admin/jumpstart/Packages/SC3.0u1/scdataservices_3_0_u1 /net/management_server_name-admin/jumpstart/Packages/SC3.0u2/scdataservices_3_0_u2 |
In the Cluster Platform 15K/9960 System Installation Guide, the user ID for the domains on the cluster nodes is documented as domain-a. It should be domaina.
In the Cluster Platform 15K/9960 System Site Planning Guide, the operating temperature range in Table 3-1 is incorrect. It should be 60 to 90 °F (16 to 32 °C).
Copyright © 2002, Sun Microsystems, Inc. All rights reserved.